MAINTENANCE
5-7
MA-5195-ESP
PS20 NON STOP+ DRUM UNLOADER MANUAL
Cleaning the capacitive sensor
It is necessary to remove any adhesive residue that may remain on the
sensor regularly (at least once every three months) to prevent any incorrect
level readings. It is also advisable to clean it when cleaning the tank or when
changing the type of adhesive.
1. With the adhesive block removed from the unit and the adhesive level
below the sensor, remove the screws from the clamp bushing.
2. Thread the screws through the bushing’s threaded extraction holes so
that it can be removed from its housing in the tank.
3. Clean the adhesive residue off the sensor, the bracket’s housing and the
sealing gasket. If the gasket is damaged, replace it with a new one.
Attention:
Do not remove the sensor from the bracket.
4. Reinstall the bracket in its housing in the tank. Ensure that the fastening
screws are properly tightened
Sensitivity adjustment of the capacitive sensor
Important:
Use the working adhesive and at the working temperature.
Warning:
Hot zone with high temperatures. Risk of burns. Use thermal
protective equipment.
Sensitivity adjustment of the capacitive sensor
1. Clean the tank as indicated in the part ‘Cleaning the tank’ of the
instruction manual of your equipment.
2. Clean the sensor by completely removing all adhesive remains.
3. Melt the adhesive at working temperature until it covers the sensor just
above it.
1
2
4
3
Summary of Contents for PS 20 NON STOP+
Page 1: ...GLUING SOLUTIONS MA 5195 ENG 010620 ADHESIVE MELTER PS20 NON STOP INSTRUCTIONS MANUAL ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 68: ...FOCKE MELER GLUING SOLUTIONS 4 42 MELTER OPERATION This page is intentionally left blank ...
Page 80: ...FOCKE MELER GLUING SOLUTIONS 6 2 TECHNICAL CHARACTERISTICS Dimensions ...
Page 81: ...ELECTRICAL DRAWINGS 7 1 MA 5195 ENG PS20 NON STOP DRUM UNLOADER MANUAL 7 ELECTRICAL DRAWINGS ...
Page 82: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 84: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DRAWING 16 17 19 18 10 11 12 13 14 15 ...
Page 86: ...FOCKE MELER GLUING SOLUTIONS 8 4 PNEUMATIC DRAWING This page is intentionally left blank ...
Page 88: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...