MA-5195-ENG
PS20 NON STOP+ DRUM UNLOADER MANUAL
MELTER OPERATION
4-7
Manual pumping permmision
Warning:
Automatic pumping permission depends on the type of set-up
and the installation conditions of the unit. For more information, please see
the ‘Automatic pumping block function’ and ‘Setting up the turning on and
activation of pumping’ sections.
When the unit reaches the programmed operating temperature (Zones in
Temperature OK), and there are no errors, the pump can be activated (READY)
or disabled (STOPPED) by pressing the ‘STOP’ key.
When the pump is deactivated(STOPPED), the red LED next to the key stays lit.
Press to
activate
pumping
STOPPED
MODE
READY
MODE
Press to
deactivate
pumping
Unit status
Symbol on the
display
Central LED
Description
Heating
The unit is heating the programmed zones.
Delay
08:31
The zones are at Temperature OK but the
‘Pumping Permission Delay’ is activated
Standby
The tank or the distributor are in standby
mode.
Inhibition
The tank or the distributor are inhibited.
Warning
The unit has an operating error but can
continue operating.
Alarm
The unit has an operation error and
continues to operate for a programmed
amount of time.
Error
The unit has an operating error and cannot
continue operating.
Zones in
Temperature OK
The zones are at the set point temperature.
Summary of Contents for PS 20 NON STOP+
Page 1: ...GLUING SOLUTIONS MA 5195 ENG 010620 ADHESIVE MELTER PS20 NON STOP INSTRUCTIONS MANUAL ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 68: ...FOCKE MELER GLUING SOLUTIONS 4 42 MELTER OPERATION This page is intentionally left blank ...
Page 80: ...FOCKE MELER GLUING SOLUTIONS 6 2 TECHNICAL CHARACTERISTICS Dimensions ...
Page 81: ...ELECTRICAL DRAWINGS 7 1 MA 5195 ENG PS20 NON STOP DRUM UNLOADER MANUAL 7 ELECTRICAL DRAWINGS ...
Page 82: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 84: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DRAWING 16 17 19 18 10 11 12 13 14 15 ...
Page 86: ...FOCKE MELER GLUING SOLUTIONS 8 4 PNEUMATIC DRAWING This page is intentionally left blank ...
Page 88: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...