FOCKE MELER GLUING SOLUTIONS
2-2
INTRODUCTION
Modes of operation
El equipo puede estar en los siguientes modos de operación:
The unit has the following operating modes:
• READY Mode (Prepared).
The melter keeps the components hot at the
programmed working temperature. The pump is kept idle, awaiting an
adhesive pump request.
• RUNNING Mode (in Operation).
The unit pumps adhesive, and all
programmed working conditions are correct.
Internal control of pumping and speed _
In this mode of
operation, the user has full control of pumping and the set speed
of the pump rotation.
Control of internal pumping and external speed_
This mode of
operation is performed through internal pumping control and
speed control by means of an external 0-10 V signal sent from the
main machine.
Control of external pumping and internal speed_
This mode of
operation is performed through external pumping control and
manual speed control.
Control of external pumping and speed_
In this working mode,
both pumping and speed are controlled from the main machine.
Speed is controlled by means of an external 0-10 V signal sent
from the main machine.
• STOPPED Mode (Pumping disabled).
The pump is kept disabled until the
pump is either manually or automatically activated.
• Heating Mode.
The unit heats the areas up to the programmed
temperature. The pump is kept disabled.
• STANDBY Mode (Low consumption).
The melter remains in standby while
maintaining all active areas at a programmable temperature. The pump
remains disabled.
• WARNING Mode.
The melter detects an incorrect operation or warns the
operator about the event. The unit can continue to operate.
• ALARM Mode.
The melter detects an operation error or warns the
operator about the event. Depending on the type of alarm, the unit may
continue to operate for a programmed amount of time.
• ERROR Mode.
The melter detects an operation error or warns the
operator about the event. The unit cannot continue to operate, and
pumping is stopped immediately. Depending on the type of error, the unit
disconnects heating from all the areas.
• OFF Mode.
The unit remains off with no areas heated and the pump
disabled. The power and pneumatic supply from the network to the unit is
maintained.
Identifying the melting equipment
When ordering replacement parts or requesting assistance from our technical
support department, you must know your melting equipment’s model and
reference numbers.
This and other technical information may be found on the identification plate,
located on the electrical cabinet on the side of the melting equipment..
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
75 rpm
50 rpm
50 rpm
49 rpm
53 rpm
PUMP 1
Real speed:
External reference 1
External permission 1
Switch 1
Real speed:
External reference 2
External permission 2
Switch 2
PUMP 2
Summary of Contents for PS 20 NON STOP+
Page 1: ...GLUING SOLUTIONS MA 5195 ENG 010620 ADHESIVE MELTER PS20 NON STOP INSTRUCTIONS MANUAL ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 68: ...FOCKE MELER GLUING SOLUTIONS 4 42 MELTER OPERATION This page is intentionally left blank ...
Page 80: ...FOCKE MELER GLUING SOLUTIONS 6 2 TECHNICAL CHARACTERISTICS Dimensions ...
Page 81: ...ELECTRICAL DRAWINGS 7 1 MA 5195 ENG PS20 NON STOP DRUM UNLOADER MANUAL 7 ELECTRICAL DRAWINGS ...
Page 82: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 84: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DRAWING 16 17 19 18 10 11 12 13 14 15 ...
Page 86: ...FOCKE MELER GLUING SOLUTIONS 8 4 PNEUMATIC DRAWING This page is intentionally left blank ...
Page 88: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...