MA-5195-ENG
PS20 NON STOP+ DRUM UNLOADER MANUAL
MELTER OPERATION
4-15
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
English
Español
Français
Deutsch
Portugues
Italiano
Česky
Polski
Nederlandse
°F
°C
Units and Language
Unit:
English
Units and Language
Unit:
English
Units and Lenguage Menu
• Units:
To select whether the temperatures are displayed in °C/°F.
•
Language configuration:
Press the desired language.
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
05
27
2019
13
35
2019-05-27
13:35
HMI (0) : S01004000 v1.0.104
TC (01) : S01201001 v1.0.83
IO (08) : S01102000 v1.0.104
Date & Time
Date
Time
HH
MM
MM
DD
YYYY
Software version
Scan the code to download the user manual
Sensor technology:
NI120
Date and time configuration
This screen allows you to view and modify the date and time data of the
system.
It also shows:
• The equipment software version.
• A QR code, to be able to download the user manual.
• The type of technology of the installed sensors.
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
Alarms
2018-05-20 10:45
A19: Over temperature applicator 2
2018-05-20 11:15
A12: Over temperature zone 6.1
2018-05-20 10:03
A66: Thermostat
2018-05-20 09:12
A53: Broken sensorzone hose 6
2018-05-20 08:32
W14: Low Temperature Tank
RESET ALL
RESET
RESET
RESET
Alarms and warnings
It displays the alarms and warnings in chronological order. It shows 5 alarms
on each screen, with a total of 3 screens.
When an alarm/warning needs to be reset for the unit to return to operation,
a button appears for you to press and confirm that the problem has been
resolved.
The ‘Delete logs’ button appears on the screen to delete all the alarm/warning
logs.
Summary of Contents for PS 20 NON STOP+
Page 1: ...GLUING SOLUTIONS MA 5195 ENG 010620 ADHESIVE MELTER PS20 NON STOP INSTRUCTIONS MANUAL ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 68: ...FOCKE MELER GLUING SOLUTIONS 4 42 MELTER OPERATION This page is intentionally left blank ...
Page 80: ...FOCKE MELER GLUING SOLUTIONS 6 2 TECHNICAL CHARACTERISTICS Dimensions ...
Page 81: ...ELECTRICAL DRAWINGS 7 1 MA 5195 ENG PS20 NON STOP DRUM UNLOADER MANUAL 7 ELECTRICAL DRAWINGS ...
Page 82: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 84: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DRAWING 16 17 19 18 10 11 12 13 14 15 ...
Page 86: ...FOCKE MELER GLUING SOLUTIONS 8 4 PNEUMATIC DRAWING This page is intentionally left blank ...
Page 88: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...