TECHNICAL CHARACTERISTICS
6-1
MA-5195-ENG
PS20 NON STOP+ DRUM UNLOADER MANUAL
6. TECHNICAL
CHARACTERISTICS
Generals
Tank capacity
Reserve tank capacity
Pumping rate
(*)
single pump
double pump (per output)
Melting rate
(*)
Number of pumps
Number of hydraulic outputs
Number of electrical outputs
Speed motor
Temperatures range
Temperature control
Max. working pressure (at 6 bar)
Max. power supply
one single pump
two single pumps
one or two double pumps
External functions
Imputs
Outputs
Electrical requeriments
Workplace temperature
Dimensions (L x W x H)
Weight
(*) Under standard conditions
Ø286 x 395 (20 kg blocks)
3.5L (used) / 10L (max.)
1, 2.5, 4 and 8 cc/rev
2x0.93, 2x1.86, 2x3.71 and 2x4.8 cc/rev
18 l/h continuous consumption with no grille control
Up to 2 single pumps or 2 double pumps
2 per pump
2 or 4 outputs (Standard version)
10-80 rpm (range 0-100 rpm)
40 to 200°C (100 to 392°F)
RTD ±0.5°C (±1°F)
Pt-100 / Ni-120 / NTC-R
80 bar (1.160 psi)
4.500 W / per phase (2 outputs)
6.120 W / per phase (4 outputs)
7.920 W / per phase (6 outputs)
6.150 W / per phase (2 outputs)
6.150 W / per phase (4 outputs)
7.920 W / per phase (6 outputs)
5.650 W / per phase (2 outputs)
6.560 W / per phase (4 outputs)
8.360 W / per phase (6 outputs)
External ON/OFF, Standby, Activity, Pumping OFF,
Zones Inhibition; VP Control
Low level, Ready, Alarm, ON/OFF, Nearly finished
block, Finished block
3N~ 400V 50/60 Hz + PE
0 to 40°C
1175 x 630 x 1500 mm
150 kg
Summary of Contents for PS 20 NON STOP+
Page 1: ...GLUING SOLUTIONS MA 5195 ENG 010620 ADHESIVE MELTER PS20 NON STOP INSTRUCTIONS MANUAL ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 68: ...FOCKE MELER GLUING SOLUTIONS 4 42 MELTER OPERATION This page is intentionally left blank ...
Page 80: ...FOCKE MELER GLUING SOLUTIONS 6 2 TECHNICAL CHARACTERISTICS Dimensions ...
Page 81: ...ELECTRICAL DRAWINGS 7 1 MA 5195 ENG PS20 NON STOP DRUM UNLOADER MANUAL 7 ELECTRICAL DRAWINGS ...
Page 82: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 84: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DRAWING 16 17 19 18 10 11 12 13 14 15 ...
Page 86: ...FOCKE MELER GLUING SOLUTIONS 8 4 PNEUMATIC DRAWING This page is intentionally left blank ...
Page 88: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...