MA-5195-ENG
PS20 NON STOP+ DRUM UNLOADER MANUAL
MELTER OPERATION
4-5
Configuration of pushing plate parameters
Two operational modes are possible according to the status of the level
detector.
• Normal Mode.
When the level detector gives the empty signal, the plate
continues to push and stops doing so when the level detector detects
adhesive again. This cycle is repeated until the up button is pushed or the
plate reaches the low position (block empty).
• ‘Auto-Press’ Mode.
If the level detector does not give an empty signal in
a configurable time, the plate will lower during a programmable time.
In this mode the tank remains pushing against the bottom, ensuring the
watertightness of the bag.
The programmable values are:
• Waiting time.
The maximum waiting time for the empty signal. After this
time, the plate starts to descend automatically.
• Pressure time.
This is the time the plate presses against the block. It is
detained after the programmed time.
• Initial pressure time.
Time that the plate descends before the pressure
time starts being counted. By programming this time it can be ensured
that the plate really presses the adhesive block.
HMI
: S02001100 v1.0.106
TC
: S02200100 v1.0.084
IO
: S02102100 v1.0.106
IO
: S02101100 v1.0.106
10 m
Auto-Press
10 s
15 s
Punch plate settings
Waiting time
Press time
Init time press
Summary of Contents for PS 20 NON STOP+
Page 1: ...GLUING SOLUTIONS MA 5195 ENG 010620 ADHESIVE MELTER PS20 NON STOP INSTRUCTIONS MANUAL ...
Page 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Page 68: ...FOCKE MELER GLUING SOLUTIONS 4 42 MELTER OPERATION This page is intentionally left blank ...
Page 80: ...FOCKE MELER GLUING SOLUTIONS 6 2 TECHNICAL CHARACTERISTICS Dimensions ...
Page 81: ...ELECTRICAL DRAWINGS 7 1 MA 5195 ENG PS20 NON STOP DRUM UNLOADER MANUAL 7 ELECTRICAL DRAWINGS ...
Page 82: ...FOCKE MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Page 84: ...FOCKE MELER GLUING SOLUTIONS 8 2 PNEUMATIC DRAWING 16 17 19 18 10 11 12 13 14 15 ...
Page 86: ...FOCKE MELER GLUING SOLUTIONS 8 4 PNEUMATIC DRAWING This page is intentionally left blank ...
Page 88: ...FOCKE MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...