1.
Insert two M8 T-nuts and rotate into position in the appropriate channel(s) of the frame.
2.
Secure the bracket (refer to
) to the T-nuts, apply Loctite 243
to two M8 screws and install with M8 split lock washers and tighten the screws to
26 N-m [230 in-lb] using a 6 mm Hex bit.
3.
Install the mounting flanges onto the NC LITE, if not already installed.
4.
Orient the NC LITE as required and secure it to the bracket, apply Loctite 243 to two
M5 x 10 mm screws and install and tighten the screws to 2.7 N-m [24 in-lb] using a
4 mm Hex bit.
NOTE:
The Loctite must cure for 2 hours at 22° C [72° F] before using the transport
system.
5.
Install an M5 T-nut in the appropriate channel of the frame and secure a nylon cable tie
holder to it using an M5 x 12 mm screw on the leg as required to secure the cables run-
ning to the NC LITE using cable ties.
Mounting Node Controller LITE and NC-12 Power Supplies
If the Node Controller is powered using the remote power supply (instead of using PoE) the
power supply should be located on the transport system stand close to the Node Controller it is
powering to minimize the length of all wiring. The power supply may be oriented in any
direction required.
Mounting Network Switches
The network switches should be located on the transport system stand close to the Node Con-
trollers they are connecting to minimize the length of all wiring. The switch can be mounted to
the same bracket used for the NC LITE (see
) and may be oriented in any direction
required.
Mounting Network Switch Power Supplies
If the Network Switch is powered using the remote power supply (instead of using PoE) the
power supply should be located on the transport system stand close to the switch it is power-
ing to minimize the length of all wiring. The power supply may be oriented in any direction
required.
NOTICE
The Node Controller LITE only supports MagneMotion’s custom Power
over Ethernet (PoE). Never connect the Node Controller LITE to a standard
PoE network as damage to internal components may result.
The NC-12 Node Controller does not support Power over Ethernet (PoE).
Never connect these Node Controllers to a PoE network as damage to inter-