Specifications and Site Requirements
Electrical Specifications
MagneMover LITE User Manual
49
Rockwell Automation Publication MMI-UM002E-EN-P - March 2016
NC-12 Node Controller
22 - 30 VDC, 20 W maximum based on configuration and operating mode. Refer to
for the mechanical drawing.
AC Power Option
The optional remote power supply for the NC-12 Node Controller requires 90 - 264 VAC @
47 - 63 Hz, single phase (phase to phase or phase to neutral), 0.7 A at 100 VAC (25 W max),
based on configuration and operating mode. Inrush current 45 A/240 VAC max. Refer to the
manufacturer’s data sheet for mechanical information.
The actual power being drawn will depend upon operations being performed, however all
power wiring must be capable of carrying the full load.
DC Power Option
DC power from a user-supplied power supply requires 22 - 30 VDC, 20 W.
The actual power being drawn will depend upon operations being performed, however all
power wiring must be capable of carrying the full load and has a limited power source or is
fused to the maximum rating of the power wiring.
CAUTION
High Voltage Hazard
90 - 264 VAC, 25 W
AC power must be disconnected before servicing.
NOTICE
Any user-supplied power supply must be NRTL/ATL approved.
NOTICE
The NC-12 Node Controller does not support Power over Ethernet (PoE).
Connecting the controller to a powered Ethernet network may damage it.
NOTICE
Connecting to the DC power connector on the NC-12 Node Controller must
be done with the power supply off. Connecting with the power supply on
may cause a short circuit at the connector, which may damage the power
supply or any other equipment being powered by that power supply.