Specifications and Site Requirements
Electrical Specifications
50
MagneMotion
Rockwell Automation Publication MMI-UM002E-EN-P - March 2016
Figure 4-43: NC-12 Node Controller Electrical Connections and Indicators
Table 4-15: NC-12 Node Controller Connections
Label
Description
Connector Type
CONSOLE
External terminal
DE-9, Male
ETHERNET
Ethernet – 10/100/1000 BaseTx
RJ-45, Female, IP-67
*
*
IP-67 mating connector is not required.
DIGITAL I/O
Digital I/O, refer to
Spring-cage clamp
RS-232
RS-232 external communications
DE-9, Male
RS-422
RS-422 motor communications
M8 Nano-Mizer, 4-Pin, Male
†
†
MagneMotion recommends that the odd number connectors be used for upstream connections and the even
number connectors be used for downstream connections.
POWER
22 - 30 VDC, 20 W
DC Power Jack, 2.0 mm Coax, Male,
M12 Thread
Ground
M6 threaded stud
‡
‡
MagneMotion requires grounding the NC-12 through the ground stud.
Table 4-16: NC-12 Node Controller Indicators
Label
Description
Indicator Type
PWR
ON – Indicates DC power is on.
Green LED
Ethernet
Console
RS-422
Digital I/O
RS-232
Front View
Ground
Power
Indicator
DC Power