Maintenance
Troubleshooting
14
MagneMotion
Rockwell Automation Publication MMI-UM002E-EN-P - March 2016
Power Related Troubleshooting
This section covers the determination of power related problems within the MagneMover
LITE transport system.
Table 7-4: Power Related Troubleshooting
Symptom
Problem Description
Corrective Action
Lights on power supplies do not
turn on.
No power or incorrect power
being supplied.
Verify the Power Cable from the
facility’s power is fully seated and
secured.
Verify the facility’s power to the
MagneMover LITE transport sys-
tem is the correct power rating.
Power supply main fuses are
blown.
Verify power supply main fuses
are not blown. Replace if neces-
sary and determine cause to pre-
vent reoccurrence.
Motors not moving vehicles at
full speed.
Power supply is not providing full
power.
Verify power supply air filter is
not dirty. Clean or replace if nec-
essary.
Verify power supply vents are not
obstructed (refer to
Transport system motion control
issues.
Review
.
One or more motors do not oper-
ate.
Power or communication to the
affected motors is lost or intermit-
tent.
Verify cables to the affected
motor(s) are fully seated and
secured.
Power supply is not providing full
power.
Verify power supply for the
affected motor is operating prop-
erly.
Verify voltage output from the
power supply.
Verify power supply Logic and
Propulsion fuses are not blown.
Replace if necessary and deter-
mine cause to prevent reoccur-
rence.