Installation
Transport System Installation
MagneMover LITE User Manual
37
Rockwell Automation Publication MMI-UM002E-EN-P - March 2016
Installing Digital I/O Wiring
Wiring for discrete digital inputs and outputs can be connected to the NC-12 Node Controllers
and used for E-Stops, Interlocks, Light Stacks, and general purpose I/O. Refer to
for the Digital I/O connection locations on the NC-12 Node Controller.
To make Digital I/O connections use 12 - 26 AWG insulated wires and connect them to the
appropriate input or output bits and to the respective COM, GND, or VDD connections.
Insert a small (e.g., #2) flat blade screwdriver into the connector release slot above the appro-
priate connector (refer to
) and rotate it in place to open the connector while insert-
ing the wire into the connector. Once the wire is fully seated, release and remove the
screwdriver. Note, ensure the connector blades are making direct contact with the wire and not
contacting the insulation.
Figure 5-21: Digital I/O Connections
Connector Release
Connector
Connector Release
Connector