Installation
Transport System Installation
16
MagneMotion
Rockwell Automation Publication MMI-UM002E-EN-P - March 2016
Securing the Transport System
The MagneMover LITE transport system should be secured to the floor to prevent system
movement. Two methods are available; securing the feet or using brackets to secure the legs.
Additionally, the beam on the MagneMover LITE should be secured to the equipment it is
interfacing with to prevent movement at the interface location by securing it directly to the
equipment.
NOTE:
Tie-downs for facilities requiring earthquake protection are the responsibility of the
user.
Tie-down Using Brackets
The legs of the MagneMover LITE frame should be secured to the facility floor to prevent
system movement by installing tie-down brackets and installing an appropriate fastener.
Figure 5-6: Bracket Tie-down
1.
Insert two M8 T-nuts and rotate into position in the appropriate channel of the leg.
2.
Apply Loctite 243 to two M8 x 16 mm screws and secure the bracket to the leg using
the screws and M8 washers. Tighten enough to secure the bracket while still allowing
it to move vertically.
NOTICE
Ensure the transport system is properly grounded to safety ground (earth).
Leg Stand Assembly
M8 T-Nut
(2X)
M8 Screw
(2X)
Bracket