Maintenance
Repair
MagneMover LITE User Manual
71
Rockwell Automation Publication MMI-UM002E-EN-P - March 2016
Replacing Z-Datums on Precision Locator Stand
The z-datums used to support the pallet while it is being secured by the Precision Locator can
be removed and replaced if they become damaged or worn due to extended use.
Required Tools and Equipment
•
100-0097-30 – Loctite 243, Thread locker Anaerobic Adhesive, Blue.
•
200-2354-xx – Z-Datum, Extended (2X)
•
100-0117-01 – Screw, SHC, Full Thd, M4 X 6 mm L, A2 SS (6X - 12X).
•
Isopropyl Alcohol.
•
Torque wrench with the following bits:
•
3 mm.
Procedure
Figure 7-31: Replace Z-Datum on Precision Locator Stand
Z-Datum
(2X)
M4 Screw
(4X)