215922
411
Revision A
Fault
Codes
Telltale
Short
Description
Full
Fault
Description
Recommended
Fix/Check
Message
SA
SPN
FMI
34
521518
1
Header
Sys
te
m
LH
Knife
Speed
ETDK
Knife
Over
Speed
LH
knife
speed
has
exceeded
200SPM
34
521519
1
Header
Sys
te
m
LH
Knife
Valve
ETDK
Bypass
Valve
LH
bypass
valve
at
100%.
Verify
valve
is
functional
34
521521
1
Header
Sys
te
m
RH
Knife
Sensor
ETDK
Sensor
Fault
RH
knife
speed
sensor
fault.
Sensor
output
not
responding
as
expected
relative
to
knife
pressure
34
521522
1
Header
Sys
te
m
RH
Knife
Speed
ETDK
Over
Speed
RH
knife
speed
has
exceeded
200SPM
34
521523
1
Header
Sys
te
m
RH
Knife
Valve
ETDK
Bypass
Valve
RH
bypass
valve
at
100%.
Verify
valve
is
functional
34
521525
1
Header
Sys
te
m
Knife
Contr
ol
ETDK
Open
Loop
ETDK
Knife
speed
contr
ol
is
in
open
loop
control
34
521528
1
Header
Sys
te
m
STW
Contr
oller
Offline
STW
Contr
oller
Offline
The
controller
is
offline.
Check
CAN
harness.
34
521536
1
Header
Sys
te
m
Knife
Contr
ol
ETDK
Max
Knife
pressure
Knife
pressure
at
maximum
(3000
PSI)
34
521537
2
Header
Sys
te
m
Knife
Contr
ol
ETDK
Min
Knife
pressure
Knife
pressure
below
minimum
(200
PSI),
with
knife
speed
sensor
reporting
a
speed.
104
521000
3
Electrical
Sys
te
m
Fuel
Level
Sender
Low
Alarm
Sensor
voltage
below
0.4V.
Check
sensor
power
supply
.
Replace
sensor
if
necessary
.
104
521000
4
Electrical
Sys
te
m
Fuel
Level
Sender
High
Alarm
Sensor
voltage
above
4.7
V.
Check
for
wiring
damage.
Replace
sensor
if
necessary
.
104
521000
5
Electrical
Sys
te
m
Fuel
Level
Sender
Low
Err
or
Sensor
voltage
below
0.025V.
Check
sensor
power
supply
.
Check
for
wiring
damage.
Replace
sensor
if
necessary
.
104
521000
6
Electrical
Sys
te
m
Fuel
Level
Sender
High
Err
or
Sensor
voltage
above
4.95
V.
Check
for
wiring
damage.
Replace
sensor
if
necessary
.
104
521000
8
Electrical
Sys
te
m
Fuel
Level
Sender
Vref
Err
or
Reference
voltage
err
or
.
Check
sensor
wiring
for
damage.
104
521003
3
Electrical
Sys
te
m
GSL
Position
Low
Alarm
Sensor
voltage
below
0.45V.
Check
sensor
power
supply
.
Replace
sensor
if
necessary
.
104
521003
4
Electrical
Sys
te
m
GSL
Position
High
Alarm
Sensor
voltage
above
4.65
V.
Check
for
wiring
damage.
Replace
sensor
if
necessary
.