•
FQXSFMA0026G: Multi-bit CE occurred on DIMM [arg1], need to restart the system for DIMM Self-
healing to attempt post package repair (PPR)
Severity: Warning
User Action:
Complete the following steps:
1. Restart the system to allow for DIMM Self-healing to attempt hard post package repair (PPR) and
confirm that event ID FQXSFMA0026I was recorded.
2. If the problem persists or if PPR attempt failed due to event ID FQXSFMA0027M or
FQXSFMA0028M, collect Service Data logs.
3. Contact Lenovo Support.
•
FQXSFMA0026I: DIMM [arg1] Self-healing, attempt post package repair (PPR) at Rank [arg2] Sub
Rank [arg3] Bank [arg4] Row [arg5] on Device [arg6]. [arg7]
Severity: Info
User Action:
Information only; no action is required.
•
FQXSFMA0027K: Invalid memory configuration (Unsupported DIMM Population) detected. Please
verify memory configuration is valid.[arg1]
Severity: Error
User Action:
Complete the following steps:
1. This event could follow an uncorrectable memory error or failed memory test. Check the log and
resolve that event first. DIMMs disabled by other errors or actions could cause this event.
2. Ensure that the DIMM are populated in the correct sequence, according to the service information for
this product.
3. If DIMMs are present and properly installed, check for any lit DIMM connector error LEDs, and if
found, reseat those DIMMs, then check logs for memory diagnostic codes.
4. Reset UEFI to default settings.
5. If problem persists, update UEFI firmware.
6. If the problem persists, collect Service Data logs.
7. Contact Lenovo Support.
•
FQXSFMA0027M: DIMM [arg1] Self-healing, attempt post package repair (PPR) failed at Rank
[arg2] Sub Rank [arg3] Bank [arg4] Row [arg5] on Device [arg6]. [arg7]
Severity: Warning
User Action:
Complete the following steps:
1. Reseat the affected DIMM (Note: The event Log might contain a recent FQXSFMA0011I event
denoting detected change in DIMM population that could be related to this problem.)
2. Boot to F1 setup and enable the DIMM. Reboot the system.
3. Update UEFI firmware to the latest version.
4. If the problem persists, collect Service Data logs.
5. Contact Lenovo Support.
172
ThinkSystem D2 Enclosure, Modular Enclosure, Modular Enclosure for 6U Configuration and ThinkSystem SD530 Compute
Node Messages and Codes Reference
Summary of Contents for 7X20
Page 225: ......
Page 226: ...Part Number SP47A24248 Printed in China 1P P N SP47A24248 1PSP47A24248 ...