1. Check Lenovo support site for an applicable service bulletin or UEFI firmware update that applies to
this error.
2. A/C cycle the system.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
•
FQXSFDD0012I: SATA Hard Drive Error: [arg1] was recovered.
Severity: Info
User Action:
Information only; no action is required.
•
FQXSFDD0012K: SATA Hard Drive Error: [arg1].
Severity: Error
User Action:
Complete the following steps:
1. Power down the server.
2. Re-insert SATA Drive to ensure it is fully connected to the backplane.
3. If the problem persists, collect Service Data logs and contact Lenovo Support.
•
FQXSFIO0005M: An intra-board UPI failure has been detected on the link between processor [arg1]
port [arg2] and processor [arg3] port [arg4].
Severity: Error
User Action:
Complete the following steps:
1. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this
error.
2. If the problem persists, collect Service Data logs.
3. Contact Lenovo Support.
•
FQXSFIO0006M: An inter-board UPI failure has been detected on the link between processor [arg1]
port [arg2] and processor [arg3] port [arg4].
Severity: Error
User Action:
Complete the following steps:
1. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this
error.
2. If the problem persists, collect Service Data logs.
3. Contact Lenovo Support.
•
FQXSFIO0007M: An error has been detected by the IIO on Bus [arg1]. The value of Global Fatal
Error Status register is [arg2]. The value of Global Non-Fatal Error Status register is [arg3]. Please
check error logs for additional downstream device error data.
Severity: Error
User Action:
Complete the following steps:
.