Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Voltage
SNMP Trap ID: 1
CIM Prefix: PLAT CIM ID: 0522
User Action:
Reseat the faulty node in D2 enclosure (AC cycle).
1. Check if multiple nodes within the D2 enclosure are reporting SysBrd Vol fault:
2. If the fault is reported by single node swap the failing node with a good node.
3. If fault follows the node please replace the system board in the compute node (trained technician
only).
4. If the fault follows the slot within the D2 enclosure please replace the shuttle (trained technician only).
5. If multi-node failure in a chassis, AC cycle entire chassis by disconnect power cords and plugging
them back into system again.
6. If problem persists do steps 2 a-c.
•
FQXSPPW2001I: [PowerSupplyElementName] has been removed from container
[PhysicalPackageElementName].
This message is for the use case when an implementation has detected a Power Supply has been
removed.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0085
User Action:
Information only; no action is required
•
FQXSPPW2002I: [PowerSupplyElementName] has returned to OK status.
This message is for the use case when an implementation has detected a Power Supply return to normal
operational status.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: Critical - Power
SNMP Trap ID: 4
CIM Prefix: PLAT CIM ID: 0087
User Action:
Information only; no action is required
•
FQXSPPW2003I: Failure no longer predicted on [PowerSupplyElementName].
This message is for the use case when an implementation has detected a Power Supply failure is no
longer predicted.
Severity: Info
Serviceable: No
Automatically notify Support: No
.
115
Summary of Contents for 7X20
Page 225: ......
Page 226: ...Part Number SP47A24248 Printed in China 1P P N SP47A24248 1PSP47A24248 ...