2. Make sure that the DIMM connectors are correctly populated for sparing mode, according to the
service information for this product.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
•
FQXSFMA0011I: Memory population change detected. [arg1]
Severity: Info
User Action:
Complete the following steps:
1. If you have added or removed DIMMs to the system, and no additional errors were detected, then
please ignore this message.
2. Check system event log for uncorrected DIMM failures and replace those DIMMs.
•
FQXSFMA0012I: The PFA of DIMM [arg1] has been deasserted.
Severity: Info
User Action:
Information only; no action is required.
•
FQXSFMA0012L: The [arg1] PFA Threshold limit has been exceeded on DIMM [arg2] at address
[arg3]. [arg4]
Severity: Warning
User Action:
Complete the following steps:
1. Reseat affected DIMM (Note: The event Log might contain a recent FQXSFMA0011I event denoting
detected change in DIMM population that could be related to this problem.)
2. Check Lenovo support site for an applicable service bulletin or firmware update that applies to this
memory error.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
•
FQXSFMA0013I: Mirror Fail-over complete. DIMM [arg1] has failed over to to the mirrored copy.
[arg2]
Severity: Info
User Action:
Check the system-event log for uncorrected DIMM failures and replace those DIMMs.
•
FQXSFMA0014I: Memory spare copy initiated. [arg1]
Severity: Info
User Action:
Information only; no action is required.
•
FQXSFMA0015I: Memory spare copy has completed successfully. [arg1]
Severity: Info
User Action:
Check system log for related DIMM failures and replace those DIMMs.