Please check event log in system management module (SMM) web interface to identify the predicted
failure.
•
FQXSPPW0005I: [PowerSupplyElementName] is operating in an Input State that is out of range.
This message is for the use case when an implementation has detected a Power Supply that has input out
of range.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0098
User Action:
Information only; no action is required
•
FQXSPPW0006I: [PowerSupplyElementName] has lost input.
This message is for the use case when an implementation has detected a Power Supply that has input
that has been lost.
Severity: Warning
Serviceable: No
Automatically notify Support: No
Alert Category: Warning - Power
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0100
User Action:
Make sure power cables are connected correctly.
•
FQXSPPW0007L: [PowerSupplyElementName] has a Configuration Mismatch.
This message is for the use case when an implementation has detected a Power Supply with a
Configuration Error.
Severity: Error
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - Power
SNMP Trap ID: 4
CIM Prefix: PLAT CIM ID: 0104
User Action:
Check the event log in system management module (SMM) and product spec. in server setup guide.
•
FQXSPPW0008I: [SensorElementName] has been turned off.
This message is for the use case when an implementation has detected a Power Unit that has been
Disabled.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Power Off
SNMP Trap ID: 23
CIM Prefix: PLAT CIM ID: 0106