Maintenance
W9272-8135-1
215
05/2020
Coolant content (air-conditioner only) - check
A low refrigerant level affects the performance of the equipment and the air-conditioner will eventually automati-
cally switch off. If you find out that the refrigerant level is too low, please contact your KUBOTA dealer.
Open the side cover (page 155).
Start the engine (page 96) and set an idle speed of 1500 1/min,
if necessary.
Set the temperature control to the "Cold" position and the fan
to level 3, then switch on the air-conditioner.
Using the sight glass (1), determine the refrigerant level ac-
cording to the table below. If the refrigerant level is too low,
please contact your KUBOTA dealer.
Close the side cover.
Avoid eye and skin contact. The refrigerant causes severe frostbite.
When working with refrigerants, always wear an eye protection.
Avoid contact of refrigerant and open flames. Burning the refrigerant produces a toxic gas.
Do not detach or deactivate any components of the air-conditioner. Please contact your KUBOTA
dealer.
This air conditioner contains fluorinated greenhouse gases (F-gases)
).
Refrigerant level is OK
Small or no bubbles in the refrigerant
Refrigerant level too low
Many large bubbles and foam in the refrigerant
No refrigerant inside
Colourless and transparent
STOP
STOP
STOP
1
1
Summary of Contents for U50-5
Page 1: ...GB COMPACT EXCAVATOR MODEL U50 5 OPERATING INSTRUCTIONS W9272 8135 1 Original 05 2020...
Page 38: ...36 W9272 8135 1 05 2020 Safety rules...
Page 54: ...52 W9272 8135 1 05 2020 Description of the machine...
Page 74: ...72 W9272 8135 1 05 2020 Assembly and functions...
Page 164: ...162 W9272 8135 1 05 2020 Operation...
Page 222: ...220 W9272 8135 1 05 2020 Maintenance...
Page 224: ...222 W9272 8135 1 05 2020 Safety inspection...
Page 234: ...232 W9272 8135 1 05 2020 Software information...
Page 235: ...Software information W9272 8135 1 233 05 2020...
Page 236: ......