110
W9272-8135-1
05/2020
Operation
Blocking and releasing the particle filter regeneration - Overview
Inhibit
indicator
Warning
light
indicator
Explanation
Measure
lights up
(yellow)
does not
glow
-
Automatic regeneration pro-
cess blocked.
The state is before a required
regeneration.
If the lock switch starts flash-
ing, then regeneration is re-
quired.
All the functions and auxiliary
ports 1 and 2 continue to be
available.
flashing
(yellow)
flashing
(yellow)
Automatic regeneration pro-
cess blocked.
The operator has to make the
necessary preparations for re-
generating the particle filter.
Make sure that no people, ani-
mals, plants and/or flammable
materials are within the imme-
diate working area. Release
the particle filter regeneration
using the inhibit switch.
Raise the engine speed until
the “Raise engine speed” indi-
cator and message disappear.
The automatic particle regener-
ation starts.
All the functions and auxiliary
ports 1 and 2 continue to be
available.
flashing
(yellow)
flashing
(red)
Automatic regeneration pro-
cess blocked.
The operator has to make the
necessary preparations for re-
generating the particle filter.
The particle filter is clogged if
the message "Engine output is
limited" is shown in the display.
The engine power is reduced
to protect the particle filter.
When the control lever lock is
lifted, the engine switches off
after 60 seconds to protect the
particle filter.
If the control lever lock is low-
ered, then the engine is not
switched off.
Make sure that no people, ani-
mals, plants and/or flammable
materials are within the imme-
diate working area. Release
the particle filter regeneration
using the inhibit switch. Raise
the engine speed until the
“Raise engine speed” indicator
and message disappear. The
automatic particle regenera-
tion starts.
All the functions and auxiliary
ports 1 and 2 continue to be
available.
flashing
(yellow)
flashing
(red)
The particle filter is clogged
with soot particles and the par-
ticle filter regeneration can no
longer start. The particle filter
must be repaired.
The engine power is reduced
to protect the particle filter.
Inform your KUBOTA dealer
immediately.
flashing
(yellow)
flashing
(red)
The particle filter has to be re-
placed.
The engine power has to be
limited to protect the particle fil-
ter.
Inform your KUBOTA dealer
immediately.
Summary of Contents for U50-5
Page 1: ...GB COMPACT EXCAVATOR MODEL U50 5 OPERATING INSTRUCTIONS W9272 8135 1 Original 05 2020...
Page 38: ...36 W9272 8135 1 05 2020 Safety rules...
Page 54: ...52 W9272 8135 1 05 2020 Description of the machine...
Page 74: ...72 W9272 8135 1 05 2020 Assembly and functions...
Page 164: ...162 W9272 8135 1 05 2020 Operation...
Page 222: ...220 W9272 8135 1 05 2020 Maintenance...
Page 224: ...222 W9272 8135 1 05 2020 Safety inspection...
Page 234: ...232 W9272 8135 1 05 2020 Software information...
Page 235: ...Software information W9272 8135 1 233 05 2020...
Page 236: ......