Operation
Refuelling the machine
Stop the engine.
Open the left service cover (page 156).
Remove the filler cap (1) by turning it anticlockwise.
Fill diesel fuel up to the base of the filler neck.
Screw on the filler cap and close the service cover.
Fill level monitor when refuelling
The momentary fill level during refuelling can be determined by means of an acoustic signal. For this, the starter
switch must be in the STOP position.
The switch (2) for the fill level monitor is located above the tank filter
neck (1).
Ensure that the starter switch is switched to the STOP position.
Press the switch (2).
The fill level monitor is enabled.
The following signals are output:
Interrupted signal
Tank is empty
Periodic signal
Tank is being filled
Continuous signal
Tank is full
Press switch (2) after refuelling to deactivate fill level monitoring.
The signal breaks off completely if the flow rate is too
low. As soon as there is enough fuel in the tank, the
signal restarts.
1
1
KX060-05_093
1
1
2
2
KX060-05_098
Summary of Contents for U50-5
Page 1: ...GB COMPACT EXCAVATOR MODEL U50 5 OPERATING INSTRUCTIONS W9272 8135 1 Original 05 2020...
Page 38: ...36 W9272 8135 1 05 2020 Safety rules...
Page 54: ...52 W9272 8135 1 05 2020 Description of the machine...
Page 74: ...72 W9272 8135 1 05 2020 Assembly and functions...
Page 164: ...162 W9272 8135 1 05 2020 Operation...
Page 222: ...220 W9272 8135 1 05 2020 Maintenance...
Page 224: ...222 W9272 8135 1 05 2020 Safety inspection...
Page 234: ...232 W9272 8135 1 05 2020 Software information...
Page 235: ...Software information W9272 8135 1 233 05 2020...
Page 236: ......