152
W9272-8135-1
05/2020
Operation
Main fuses
Disconnect the negative terminal of battery.
Remove the main fuse box (1).
Open the main fuse box cap (1) and cover (2) then remove the
bolts (3).
Remove the burnt out main fuse from the main fuse box (1) and
replace it.
Fuse layout:
A
Alternator (80 A)
C
Main Power (1) (60 A)
C
Main Power (2) (50 A)
D
CRS (30 A)
ECU fuse
Open the mini fuse box cover (1).
Remove the fuse (E) and replace it.
E
ECU Main (+B) (10 A)
1
1
KX060-05_102
A
A B
B C
C D
D
1
1
E
E