![Kubota U50-5 Operating Instructions Manual Download Page 208](http://html1.mh-extra.com/html/kubota/u50-5/u50-5_operating-instructions-manual_2008527208.webp)
206
W9272-8135-1
05/2020
Maintenance
Battery - charge
Make the battery accessible.
For refillable-type batteries, check the electrolyte level in the battery, add distilled water if required.
Remove the negative terminal cover and take off the cable clamp. Move the clamp to the side so as to avoid
contact with the negative terminal.
Remove the positive terminal cover.
Connect the battery charger to the battery according to the instructions of the charger manufacturer. Choose
the normal (gentle) charging method.
Clean the battery after charging. For refillable-type batteries, replenish the electrolyte, if necessary.
For refillable-type batteries, check the acid density with a hydrometer. The acid density should be between
1.24 and 1.28 kg/l. If the acid density differs considerably among the individual cells of a battery, the battery
probably has a defect. Check the affected battery with a battery tester and contact trained personnel.
Battery acid is very caustic. Avoid contact with battery acid under all circumstances. If clothing, skin
or eyes have come in contact with battery acid, rinse the affected parts immediately with water. If the
eyes are affected, immediately seek medical attention! Neutralise spilled battery acid immediately.
When servicing a battery, always wear suitable protective gloves and eye protection.
Charge batteries only in sufficiently ventilated rooms. Smoking, uncovered lights or fire are not al-
lowed in these rooms.
Explosive gas is created when charging batteries. Open flames can cause an explosion.
For refillable-type batteries, remove the plugs when charging batteries that are virtually empty. If the
batteries are merely being recharged, the plugs can be left in the batteries.
The battery can only be charged if the starter switch is in the STOP position and the key removed.
When disconnecting and connecting the battery, always observe the specified order
risk of short
circuit.
STOP
STOP
Summary of Contents for U50-5
Page 1: ...GB COMPACT EXCAVATOR MODEL U50 5 OPERATING INSTRUCTIONS W9272 8135 1 Original 05 2020...
Page 38: ...36 W9272 8135 1 05 2020 Safety rules...
Page 54: ...52 W9272 8135 1 05 2020 Description of the machine...
Page 74: ...72 W9272 8135 1 05 2020 Assembly and functions...
Page 164: ...162 W9272 8135 1 05 2020 Operation...
Page 222: ...220 W9272 8135 1 05 2020 Maintenance...
Page 224: ...222 W9272 8135 1 05 2020 Safety inspection...
Page 234: ...232 W9272 8135 1 05 2020 Software information...
Page 235: ...Software information W9272 8135 1 233 05 2020...
Page 236: ......