Operator’s Guide
Cleaning the Densitometer Calibration Plate
The densitometer is mounted in the paper outlet.
1. Loosen the screw (2) and remove the front cover of the paper outlet (1).
1
2
2. Loosen the knurled screws (1) on the right and left side on the guide plate of the
densitometer unit.
3. Turn the densitometer unit (2) over and clean the calibration plate with a damp
cloth.
4. Clean the guide plates with a damp lint free cloth.
5. Fasten the densitometer unit again with the knurled screws.
6. Fasten the cover of the paper outlet.
CAUTION:
Have a service technician replace any damaged calibration
plates.
8-20