85
Function
code
Name
Descriptions
Unit
Factory
setting
Modif.
Setting
range
16~36
:
Reserved
A6.29
Functions of
terminal AO2
Same as A6.28
1
0
○
0~36
A6.30
Gain of AO1
0.0
%
~200.0%
0.1%
100.0%
○
0~2000
A6.31
Zero offset
calibration of AO1
-100.0%~100.0%
0.1%
0.0
○
0~2000
A6.32
Reserved
A6.33
Reserved
A6.34
AI1 filter
0.01~10.00s
0.01s
0.05
○
1~1000
A6.35
AI2 filter
0.01~10.00s
0.01s
0.05
○
1~1000
A6.36
Reserved
○
0~1
A6.37
Analog input zero
offset calibration
0~1
1
0
○
0~20000
A6.38
Gain of AI1
0.00%~200%
0.01%
110%
○
0~20000
A6.39
Gain of AI2
0.00%~200%
0.01%
110%
0~20000
A6.40
Reserved
0.00%~200%
0.01%
110%
0~20000
A6.41
Zero offset value
AI1
0~65535
1
3584
×
0~65535
A6.42
Zero offset value
AI2
0~65535
1
3584
×
0~65535
A6.43
Reserved
0~65535
1
3584
×
0~65535
A6.44
Setting value of
timer 1
0.0~10.0s
0.1s
0.0
○
1~100
A6.45
Setting value of
timer 2
0~100s
1s
0
○
1~100
A6.46
Target value of
counter
0~65535
1
100
○
0~65535
A6.47
Intermediate value
of counter
0~65535
1
50
○
0~65535
Group A7
:
Reserved
Group A8
:
Fault parameters
A8.00
Protective action
of relay
Unit’s place of LED:
Action selection for under-voltage
fault indication.
0:Disable
1
0000
×
0~1111H