53
helpful to improve the system output accuracy and
stability.
Fig.6-43 Error limit
C1.15 Close-loop regulation characteristic 0
、
1
【
0
】
0: Positive
Set C1.15 to 0 if the motor speed is required to be
increased with the increase of the reference.
1: Negative
Set C1.15 to 1 if the motor speed is required to decrease
with the increase of the reference.
C1.16 Integral regulation
selection
0
、
1
【
0
】
0: Stop integral regulation when the frequency reaches
the upper and lower limits
1: Continue the integral regulation when the frequency
reaches the upper and lower limits
It is recommended to disable the integral regulation for
the system that requires fast response.
C1.17 Preset close-loop
frequency
0.00
~
1000.0Hz
【
0.00Hz
】
C1.18 Holding time of
preset close-loop
frequency
0.0
~
3600.0s
【
0.0s
】
This function can make the close-loop regulation enter
stable status quickly.
When the close-loop function is enabled, the frequency
will ramp up to the preset close-loop frequency (C1.17)
within the Acc time, and then the drive will start
close-loop operation after operating at the preset
frequency for certain time(defined by C1.18).
Fig.6-44 Preset frequency of close-loop operation
Note:
You can disable the function by set both C1.17 and
C1.18 to 0.
C1.19 Preset close-loop
reference 1
-
10.00
~
10.00V
【
0.00V
】
C1.20 Preset close-loop
reference 2
-
10.00
~
10.00V
【
0.00V
】
C1.21 Preset close-loop
reference 3
-
10.00
~
10.00V
【
0.00V
】
C1.22 Preset close-loop
reference 4
-
10.00
~
10.00V
【
0.00V
】
C1.23 Preset close-loop
reference 5
-
10.00
~
10.00V
【
0.00V
】
C1.24 Preset close-loop
reference 6
-
10.00
~
10.00V
【
0.00V
】
C1.25 Preset close-loop
reference 7
-
10.00
~
10.00V
【
0.00V
】
C1.26 Preset close-loop
reference 8
-
10.00
~
10.00V
【
0.00V
】
C1.27 Preset close-loop
reference 9
-
10.00
~
10.00V
【
0.00V
】
C1.28 Preset close-loop
reference 10
-
10.00
~
10.00V
【
0.00V
】
C1.29 Preset close-loop
reference 11
-
10.00
~
10.00V
【
0.00V
】
C1.30 Preset close-loop
-
10.00
~
10.00V
【
0.00V
】
Error limit
Feedback value
Ooutput
frequency
Time
Time
Holding time of
Preset frequency
Output frequency
Preset frequency
T(time)
Reference