Chapter 6 Parameter Introductions
Note
:
6.1 Group A0
A0.00 User password
00000
~
65535
【
00000
】
This function is used to prevent the irrelevant personnel
from inquiring and changing the parameter as to protect
the safety of the inverter parameters.
0000: No password protection.
Set password:
Input four digits as user password, and press ENTER
key for confirmation. After 5 minutes without any other
operation,the password will be effective automatically.
Change password:
Press MENU key to enter the password verification
status. Input correct password and it enters parameter
editing status. Select A0.00 (parameter A0.00 displayed
as 00000).Input new password and press ENTER key for
confirmation. After 5 minutes without any other
operation, the password will be effective automatically.
Note:
Please safekeeping the user password.
A0.01 Control mode
0
~
2
【
0
】
0: Vector control without PG (Open loop vector control)
It is a vector control mode without speed sensor
feedback.It is applicable to most applications.
1: Reserved
2:V/F control
It is used to control voltage/frequence constantly.It is
applicable to most application, especially for the
application of one drive driving multiple motors.
A0.02 Main reference
frequency selector
0
~
4
【
0
】
0: Digital setting.
The initial reference frequency is the value of A0.03.
It can be adjusted via
▲
and
▼
key,or via terminal
UP/DOWN.
1: Set via AI1 terminal.
The reference frequency is set by analog input via
terminal AI1 and the voltage range is -10V~10V. The
relationship between voltage and reference frequency
can be set in Group A3.
2: Set via AI2 terminal.
The reference frequency is set by analog input via
terminal AI2 and the voltage range is -10V~10V. The
relationship between voltage and reference frequency
can be set in Group A3.
3:Set via potentiometer.
A0.03 Set the operating
frequency in digital mode
Range: Lower limit of
frequency ~upper limit
of frequency
【
50.00Hz
】
When the reference frequency is set in digital
mode(A0.02
=
0), this setting of this parameter is the
drive’s initial frequency value.
A0.04 Methods of inputting
operating commands
0
~
2
【
1
】
CV100 has two control modes.
0: Panel control: Input operating commands via panel
Start and stop the drive by pressing RUN, STOP and M
on the panel.
1: Terminal control: Input operating commands via
terminals.
Use external terminals Xi(Set function code
A6.00~A6.04 to 1 and 2),M Forward, M Reverse to start
and stop the drive.
2:Modbus communication.
A0.05 Set running direction
0
~
1
【
0
】
This function is active in panel control mode and serial
XX
. XX
YYYYYYYY
N1
~
N2
【
D
】
Parameter
No.
Parameter
Name
Range
Default
value