31
Fig.6-13 S curve Acc/Dec
S curve Acc/Dec mode can smooth acceleration and
deceleration,suitable for application like lift,conveyer
belt.
A4.01 Acc time 2
0.1
~
6000.0s
【
6.0s
】
A4.02 Dec time 2
0.1
~
6000.0s
【
6.0s
】
A4.03 Acc time 3
0.1
~
6000.0s
【
6.0s
】
A4.04 Dec time 3
0.1
~
6000.0s
【
6.0s
】
A4.05 Acc time 4
0.1
~
6000.0s
【
6.0s
】
A4.06 Dec time 4
0.1
~
6000.0s
【
6.0s
】
Acc time is the time taken for the motor to accelerate
from 0Hz to the maximum frequency (as set in A0.08),
see t
2
in Fig.6-12. Dec time is the time taken for the
motor to decelerate from maximum frequency (A0.08)
to 0Hz, see t
2
in Fig.6-12.
CV100 define three kinds of Acc/Dec time,and the
drive’s Acc/Dec time 1~4 can be selected by different
combinations of control terminals, refer to the
introductions of A6.00~A6.04 for the definitions of
terminals used to select Acc/Dec time.
A4.07
S curve acceleration
starting time
10.0%~50.0%
(Acc time)
【
20.0%
】
A4.08
S curve acceleration
ending time
10.0%~70.0%
(Acc time)
【
20.0%
】
A4.09
S curve deceleration
starting time
10.0%~50.0%
(Dec time)
【
20.0%
】
A4.10
S curve deceleration
ending time
10.0%~70.0%
(Dec time)
【
20.0%
】
A4.07~A4.10 is only valid when A4.00 is set as 1 (S
curve Acc/Dec mode),and it must make sure
A4.07+A4.08≤90%
, A4.09+ A4.10
≤
90%,as shown in
Fig.6-14.
Fig.6-14 Acc/Dec starting time and ending time
A4.11 Quick start-stop selctor 0~3
【
0
】
0
:
Disable
1
:
Quick start,normal stop
2
:
Normal start,quick stop
3
:
Quick start,quick stop
A4.12 Start ACR-P
0.1~200.0
【
20.0
】
A4.13 Start ACR-I
0.000
~
10.000s
【
0.200s
】
A4.14 Start AVR-P
0.1~200.0
【
20.0
】
A4.15 Start AVR-I
0.000
~
10.000s
【
0.200s
】
A4.16 Stop ACR-P
0.1~200.0
【
20.0
】
A4.17 Stop ACR-I
0.000
~
10.000s
【
0.200s
】
A4.18 Stop AVR-P
0.1~200.0
【
20.0
】
A4.19 Stop AVR-I
0.000
~
10.000s
【
0.200s
】
6.6 Group A5
A5.00:Reserved
A5.01 ASR1-P
0.1
~
200.0
【
20.0
】
A5.02 ASR1-I
0.000
~
10.000s
【
0.200s
】
A5.03 ASR1 output filter
0
~
8
【
0
】
A5.04 ASR2-P
0.1
~
200.0
【
20
】
A5.05 ASR2-I
0.000
~
10.000s
【
0.200s
】
A5.06 ASR2 output filter
0
~
8
【
0
】
A5.07 ASR1/2 switching
frequency
0
~
100.0%
【
10.0Hz
】