83
Function
code
Name
Descriptions
Unit
Factory
setting
Modif.
Setting
range
14
:
Swing limit
15
:
Drive ready (RDY)
16
:
Drive fault
17
:
Switching signal of host
18
:
Reserved
19
:
Torque limiting
20: Drive running forward/reverse
21: Timer 1 reach
22: Timer 2 reach
23: Preset counter reach
24: Intermediate counter reach
Others:Reserved
A6.15
Bi-direction
pen-collector
output terminal Y2
Same as A6.14
1
1
×
0~50
A6.16
Output functions
of relay R1
The same as A6.14
1
15
×
0~50
A6.17
Reserved
1
16
×
0~20
A6.18
Ouput terminal’s
positive and
negative logic
Binary setting:
0: Terminal is enabled if it is
connected to
corresponding common terminal,
and disabled if it is disconnected.
1: Terminal is disabled if it is
connected to
corresponding common terminal,
and
enabled is it is disconnected.
Unit’s place of LED
:
BIT0
:
Y1
BIT2
:
R1
Ten’s place of LED
:
Reserved
1
0
○
0~1FH
A6.19
Frequency arriving
signal (FAR)
0.00~300.00Hz
0.01Hz
2.50Hz
○
0~30000
A6.20
FDT1 level
0.00~300.00Hz
0.01Hz
50.00Hz
○
0~30000