90
Function
code
Name
Descriptions
Unit
Factory
setting
Modif.
Setting
range
b2.04
Droop control
0
:
Disable
,
0.01~10.00Hz
0.01
0.00Hz
○
0~1000
b2.05
Auto current
limiting threshold
20.0%~200.0%Ie
0.1%
150.0%
×
200~2000
b2.06
Frequency
decrease
rate when current
limiting
0.00~99.99Hz/s
0.01Hz/
S
10.00
Hz/s
○
0~9999
b2.07
Auto current
limiting
selection
0:Invalid at constant speed
1:Valid at constant speed
Note:It is valid all the time at
Acc/Dec
1
1
×
0~1
b2.08
Gain of Slip
compensation
0.0~300.0%
0.1
%
100.0
%
○
0~3000
b2.09
Slip compensation
limit
0.0~250.0%
0.1
%
200.0
%
○
0~2500
b2.10
Slip compensation
time constant
0.1~25.0s
0.1s
2.0s
○
0~250
b2.11
auto energy-saving
function
0
:
Disable
1
:
Enable
1
0
×
0~1
b2.12
Frequency
decrease
rate at voltage
compensation
0.00~99.99Hz/s
0.01Hz/
S
10.00
Hz/s
○
0~9999
b2.13
Zero-frequency
operation
threshold
0.00~300.00Hz
0.01Hz
0.50Hz
○
0~30000
b2.14
Zero-frequency
Hysteresis
(
Reserved
)
0.00~300.00Hz
0.01Hz
0.00Hz
○
0~30000
b2.15
Fan control
(
Reserved
)
0:Auto operation mode
1:Fan operate continuously when
power is on
Note: 1.Continue to operate for 3
minutes .
2.This parameter is only valid for
1
0
×
0~1