35
with
▲
and
▼
keys on the panel, which enables remote
control. This terminal is enabled when A0.02=0 or
A0.04=1. Increase or decrease rate is determined by
A2.02 and A2.03.
15: Switch to panel control.
It is used to set the control mode as panel control.
16: Switch to terminal control
It is used to set the control mode as terminal control
17: Reserved.
18: Main reference frequency via AI1
19: Main reference frequency via AI2
20: Reseved
21: Main reference frequency via DI
These functions are used to set the main reference
frequency controlled by AI1,AI2 or DI.
22: Auxiliary reference frequency invalid.
Auxiliary reference frequency is invalid when the
terminal activate
23~26: Reserved.
27~30: Preset frequency selection.
Up to 15 speed references can be set through different
ON/OFF combinations of these terminals K4, K3, K2
and K1.
Table 6-3 On/Off combinations of terminals
The frequency references will be used in multiple speed
operation. Following is an example: Definitions of
terminals X1, X2, X3and X4 as following:
After setting A6.00 to 27, A6.01 to 28 and A6.03 to 30,
terminals X1~X4 can be used in multiple speed
operation, as shown in Fig. 6-18.
Fig.6-18 Multi-step speed operation
31
~
32
:
Acc/Dec time selection
Table 6-4 Acc/Dec time selection
Terminal 2
Terminal1
Acc/Dec time selection
OFF
OFF
Acc time 1/Dec time 1
OFF
ON
Acc time 2/Dec time 2
ON
OFF
Acc time 3/Dec time 3
ON
ON
Acc time 4/Dec time 4
K4
K3
K2
K1
Frequency setting
OFF OFF
OFF
OFF
Common operating
frequency
OFF OFF
OFF
ON
Preset frequency1
OFF OFF
ON
OFF
Preset frequency 2
OFF OFF
ON
ON
Preset frequency 3
OFF
ON
OFF
OFF
Preset frequency 4
OFF
ON
OFF
ON
Preset frequency 5
OFF
ON
ON
OFF
Preset frequency 6
OFF
ON
ON
ON
Preset frequency 7
ON
OFF
OFF
OFF
Preset frequency 8
ON
OFF
OFF
ON
Preset frequency 9
ON
OFF
ON
OFF
Preset frequency 10
ON
OFF
ON
ON
Preset frequency 11
ON
ON
OFF
OFF
Preset frequency 12
ON
ON
OFF
ON
Preset frequency 13
ON
ON
ON
OFF
Preset frequency 14
ON
ON
ON
ON
Preset frequency 15
K
4
K
K
2
K
3
Speed 1
Output frequency
Time
Common
command
Speed 15
Common
Operating
frequency