![Kinco CV100 Series Manual Download Page 92](http://html1.mh-extra.com/html/kinco/cv100-series/cv100-series_manual_1967653092.webp)
89
Function
code
Name
Descriptions
Unit
Factory
setting
Modif.
Setting
range
b1.03
V/F frequency
value F2
B1.05 ~B1.01
0.01Hz
0.00Hz
×
0~30000
b1.04
V/F voltage value
V2
B1.06~B1.02
0.1%
0.0%
×
0~1000
b1.05
V/F frequency
value F1
0.00~B1.03
0.01Hz
0.00Hz
×
0~30000
b1.06
V/F voltage value
V1
0~B1.04
0.1%
0.0%
×
0~1000
b1.07
Cut-off point used
for manual torque
boost
0.0%~50.0%( Corresonding to
A0.12)
0.1%
10.0%
○
0~500
b1.08
AVR function
0
:
Disable
1
:
Enable all the time
2
:
Disabled in Dec process
1
2
×
0~2
Group b2:Enhanced parameters
b2.00
Carrier wave
frequency
2.0~15.0KHz
0.1
8.0
○
20~150
b2.01
Auto adjusting of
CWF
0
:
Disable
1
:
Enable
1
1
○
0~1
b2.02
Voltage adjustment
selection
Unit’s place of LED:
Over-voltage at stall Selection
0:Disable(When install brake
resistor)
1:Enable
Ten’s place of LED:
Not stop when instantaneous stop
function selection
0:Disable
1:Enable(Low voltage
compensation)
Hundred’s place of LED:
Overmodulation selection
0:Disable
1:Enable
1
001
×
0~111H
b2.03
Overvoltage point
at stall
120.0%~150.0%Udce
0.1%
140.0%
×
1200~150
0