87
Function
code
Name
Descriptions
Unit
Factory
setting
Modif.
Setting
range
protection mode
selection
1:Common mode (with low speed
compensation)
2: Variable frequency motor
(without low speed compensation)
A8.04
Auto reset times
0
:
No function
1~100
:
Auto reset times
Note: The IGBT protection (E010)
and external equipment fault (E015)
cannot be reset automatically.
1
0
×
0~100
A8.05
Reset interval
2.0~20.0s/time
0.1s
5.0s
×
20~200
A8.06
Fault locking
function selection.
0:Disable.
1:Enable.
1
0
×
0~1
Group b0:Motor parameters
b0.00
Rated power
0.4~999.9KW
0.1
0
×
4~9999
b0.01
Rated voltage
0~ rated volotage of drive
1
0
×
0~999
b0.02
Rated current
0.1~999.9A
0.1A
Depende
nt
on
drive’s
model
×
1~9999
b0.03
Rated frequency
1.00~1000.00Hz
0.01Hz
Depende
nt
on
drive’s
model
×
100~3000
0
b0.04
Number of
polarities of motor
2~24
1
4
×
2~24
b0.05
Rated speed
0~60000RPM
1RPM
1440RP
M
×
0~60000
b0.06
Resistance of
stator %R1
0.00%~50.00%
0.01%
Depende
nt
on
drive’s
model
×
0~5000
b0.07
Leakage
inductance %Xl
0.00%~50.00%
0.01%
Depende
nt
on
×
0~5000