Data Analysis Features
All about Trace Math
466 Keysight N9927-90001 User’s Guide
All about Trace Math
Trace Math is available in
CAT
(excluding DTF measurements),
NA
Mode, and FOPS (under USB
Power Meter mode).
A trace is a series of measurement data points that are connected to form a line. This ‘live’ data
trace is updated as data points are measured.
A memory trace is a live trace that has been stored in the FieldFox volatile memory. It then becomes
static, meaning it is not updated with measurements. It can be displayed on the screen by itself, or
with a data trace for comparison purposes.
— In NA mode, memory traces are the same color as data).
— In CAT mode and FOPS, the data trace is displayed in
yellow
and the memory trace is displayed
in
blue
.
How to display data and memory traces
— Press
Trace 6
.
— Press
Math and Memory
then
Data->Mem
to store the current live trace into memory. A ‘beep’
sounds to confirm the data trace has been saved to memory. There is no display annotation that
indicates that the memory trace has been stored.
— Press
Data
to view only the data trace.
— Press
Memory
to view only the memory trace.
— Press
Data & Memory
to view both the live trace and the stored memory trace.
How to perform Trace Math
Trace math is performed between a live trace and a memory trace. When one of the following math
operations are selected, the yellow data trace displays the current measurement with the selected
trace math applied. The math operation symbol indicated below in [brackets] is displayed on the
lower left corner of the screen.
— Press
Trace 6
.
— If not already stored, press
Data->Mem
to store the current live trace into memory.
— Then
Data Math
.
— Then choose one of the following:
—
Data + Mem
[D+M] Current measurement data is added to the data in memory.
—
Data – Mem
D-M] Current measurement data is subtracted from the data in memory.
Noise Figure (NF—Opt. 356) does not have trace math, but does have the
ability to display data and memory traces. Refer to
.
Summary of Contents for N9913A
Page 6: ...6 ...
Page 106: ...106 Keysight N9927 90001 User s Guide NA Network Analyzer Mode NA Mode Settings ...
Page 202: ...202 Keysight N9927 90001 User s Guide SA Spectrum Analyzer Mode Channel Measurements ...
Page 444: ...444 Keysight N9927 90001 User s Guide Noise Figure Mode Option 356 CPU2 Only Troubleshooting ...
Page 470: ...Data Analysis Features All about Scale Settings 470 Keysight N9927 90001 User s Guide ...
Page 546: ...546 Keysight N9927 90001 User s Guide Connector Care Review ...
Page 548: ...548 Keysight N9927 90001 User s Guide Connector Care Review ...
Page 550: ...550 Keysight N9927 90001 User s Guide Specifications Data Sheet ...
Page 553: ...553 Keysight Handheld Analyzers N99xxA User s Guide D Korean Battery Safety Translation ...
Page 554: ...554 Keysight N9927 90001 User s Guide Korean Battery Safety Translation ...
Page 556: ...556 Keysight N9927 90001 User s Guide Keysight Software End User Licensing Agreement EULA ...
Page 557: ...Keysight N9927 90001 User s Guide 557 Keysight Software End User Licensing Agreement EULA ...
Page 558: ...558 Keysight N9927 90001 User s Guide Keysight Software End User Licensing Agreement EULA ...
Page 565: ......