322 Keysight N9927-90001 User’s Guide
Pulse Measurements Mode – Option 330
Pulse Measurement Settings
—
Zoom Time/div
While monitoring the blue vertical posts on the primary
trace, enter a value for the zoom window span using the numeric keypad,
the ?|? arrows, or the rotary knob.
—
Trace 1
Press to select
Tr 1
. This can also be done by using the
arrows. Select a trace before making trace settings, such as Scale.
—
Zoom Trace
Press to select the zoom trace.
Scale
For Meter-style measurements, learn how to set Scale, Relative and Offset
Power, display Units, and Resolution beginning in
.
How to set Scale for Trace Graph measurements
— Select a trace to scale using the
arrows.
— Press
Scale / Amptd
— Then choose from the following methods:
—
Autoscale
Automatically adjusts the Y-axis to comfortably fit the Minimum
and Maximum amplitude of the trace on the screen.
— Set Scale, acquisition, and Reference Position:
—
Scale
Manually enter a
scale per division
to view specific areas of
the trace.
—
Ref Level
Manually set the value of the reference line. Enter a
negative value by pressing
Run/Hold (+/-)
either before or after
typing a value.
—
Ref Pos
Manually set the position of the reference line. Values must
be between 0 (TOP line) and 10 (BOTTOM line).
—
Offset ON
Enable Offset. When only trace 1 is visible,
Offset ON
appears to the left of the trace.
—
Offset Val
Enter a value by which all amplitude values will be offset.
This can have the effect of virtually removing a component from the
measurement path. A positive value compensates for a component
with loss. A negative value compensates for a component with gain.
Offset values are limited to +/- 100 dB.
Averaging
Averaging helps to reduce the effects of random noise on a measurement. The
more measurements that are averaged, the greater the amount of noise
reduction. Averaging is allowed for all pulse measurements.
Averaging is performed in the USB Power Sensor before the data is sent to the
FieldFox.
Summary of Contents for N9913A
Page 6: ...6 ...
Page 106: ...106 Keysight N9927 90001 User s Guide NA Network Analyzer Mode NA Mode Settings ...
Page 202: ...202 Keysight N9927 90001 User s Guide SA Spectrum Analyzer Mode Channel Measurements ...
Page 444: ...444 Keysight N9927 90001 User s Guide Noise Figure Mode Option 356 CPU2 Only Troubleshooting ...
Page 470: ...Data Analysis Features All about Scale Settings 470 Keysight N9927 90001 User s Guide ...
Page 546: ...546 Keysight N9927 90001 User s Guide Connector Care Review ...
Page 548: ...548 Keysight N9927 90001 User s Guide Connector Care Review ...
Page 550: ...550 Keysight N9927 90001 User s Guide Specifications Data Sheet ...
Page 553: ...553 Keysight Handheld Analyzers N99xxA User s Guide D Korean Battery Safety Translation ...
Page 554: ...554 Keysight N9927 90001 User s Guide Korean Battery Safety Translation ...
Page 556: ...556 Keysight N9927 90001 User s Guide Keysight Software End User Licensing Agreement EULA ...
Page 557: ...Keysight N9927 90001 User s Guide 557 Keysight Software End User Licensing Agreement EULA ...
Page 558: ...558 Keysight N9927 90001 User s Guide Keysight Software End User Licensing Agreement EULA ...
Page 565: ......