Keysight N9927-90001 User’s Guide 171
SA (Spectrum Analyzer) Mode
SA Mode Settings
— Enter a value using the numeric keypad, the
arrows, or the rotary
knob.
— Then select a multiplier key or press
Enter
. Learn more in
.
Auto Trigger Time
While waiting for a valid trigger signal,
Wait
is annotated in the top left corner
of the FieldFox screen.
If a valid trigger signal is not received before the specified Auto Trig Time, a
sweep will occur automatically.
Enter
0
to set Auto Trigger
OFF
. When Auto Trigger is OFF, the FieldFox does
NOT sweep unless a valid trigger signal is received.
— Press
Sweep 3
— Then
Trigger Settings
— Then
Auto Trigger [current setting]
— Enter an Auto Trig Time using the numeric keypad.
— Then select a multiplier key. See
“Multiplier Abbreviations” on page 41
Trigger Position
Available ONLY in zero span measurements, this setting is an easy way to
automatically set the Trigger Delay by positioning the trigger event (also
known as T-zero) at any graticule along the X-axis. With T-zero in the center of
the screen, you can zoom in and out by increasing or decreasing the sweep
time. Using the Trigger Position and Sweep Time settings is a quick and
efficient way to examine artifacts of a pulse, much easier than trying to set the
Trigger Delay manually.
When Trigger Position is set to OFF, the Trigger Delay softkey is not available.
The amount of Trigger Delay that is being used is displayed on the softkey. The
Trigger Position is annotated on the screen. Learn how in the following section.
— Press
Sweep 3
— Then
Trigger Settings
— Then
Trig Position
. If Sweep Time is longer than 0.15 sec, this softkey is
grayed out.
—
ON
: The position of T-zero is set by the trigger delay.
—
OFF
: Select, then enter a position value from 0 to 10 using the numeric
keypad, the
arrows, or the rotary knob.
——
0
: T-zero occurs at the left graticule.
——
5
: T-zero occurs at the center of the screen.
Summary of Contents for N9913A
Page 6: ...6 ...
Page 106: ...106 Keysight N9927 90001 User s Guide NA Network Analyzer Mode NA Mode Settings ...
Page 202: ...202 Keysight N9927 90001 User s Guide SA Spectrum Analyzer Mode Channel Measurements ...
Page 444: ...444 Keysight N9927 90001 User s Guide Noise Figure Mode Option 356 CPU2 Only Troubleshooting ...
Page 470: ...Data Analysis Features All about Scale Settings 470 Keysight N9927 90001 User s Guide ...
Page 546: ...546 Keysight N9927 90001 User s Guide Connector Care Review ...
Page 548: ...548 Keysight N9927 90001 User s Guide Connector Care Review ...
Page 550: ...550 Keysight N9927 90001 User s Guide Specifications Data Sheet ...
Page 553: ...553 Keysight Handheld Analyzers N99xxA User s Guide D Korean Battery Safety Translation ...
Page 554: ...554 Keysight N9927 90001 User s Guide Korean Battery Safety Translation ...
Page 556: ...556 Keysight N9927 90001 User s Guide Keysight Software End User Licensing Agreement EULA ...
Page 557: ...Keysight N9927 90001 User s Guide 557 Keysight Software End User Licensing Agreement EULA ...
Page 558: ...558 Keysight N9927 90001 User s Guide Keysight Software End User Licensing Agreement EULA ...
Page 565: ......