Keysight N9927-90001 User’s Guide 383
Channel Scanner (Option 312)
How to Set Up Channel Scanner
—
Time Interval
1 sec to 3,000 seconds or
—
Distance Interval
from 1m to 10 km
—
When done, press
Back
3.
Press
Save Recall Rec-Playback
>
File Type
CSV or KLM
4.
To begin recording: Press
Record
If Auto Save is On (default) Measurements are stored automatically
accorded to the specified time or distance interval values. Refer to step
5.
Optional:
Auto Save
ON (default)—When Auto Save is on, during
recording, the FieldFox stores intermediate results in a temporary file. If
the power fails during recording you can retrieve the results. Select
Recall
Log File
. Select the temporary file name.
Press
Record Settings
>
Auto Save On Off
6.
When done press
Stop
or
Esc
. The files save dialog is displayed. Edit the
file name where the file results will be stored.
7.
Press
Done
8.
Press
Back
Playing a Recorded Log and Viewing the Spectrogram
To play the log results:
1.
Press
RData Logginge
>
>Play
2.
Then choose:
—
Optional: Use the RPG (fine adjust) or the arrow keys (coarse adjust)
to change the color bar.
—
Position
to change the position along the time record’s
results. Recording must be Paused to use Position.
—
Red Limit
to change the color bar.
—
Blue Limit
to change the color bar.
3.
Press
Stop
or
Esc
to exit the log recording.
To pause the log play:
1.
Optional: Press
Pause Resume
to pause or resume the log recording.
2.
Then choose:
—
Optional: Use the RPG (fine adjust) or the arrow keys (coarse adjust)
to change the color bar.
—
Position
to change the position along the time record’s
results.
—
Red Limit
to change the color bar.
Summary of Contents for N9913A
Page 6: ...6 ...
Page 106: ...106 Keysight N9927 90001 User s Guide NA Network Analyzer Mode NA Mode Settings ...
Page 202: ...202 Keysight N9927 90001 User s Guide SA Spectrum Analyzer Mode Channel Measurements ...
Page 444: ...444 Keysight N9927 90001 User s Guide Noise Figure Mode Option 356 CPU2 Only Troubleshooting ...
Page 470: ...Data Analysis Features All about Scale Settings 470 Keysight N9927 90001 User s Guide ...
Page 546: ...546 Keysight N9927 90001 User s Guide Connector Care Review ...
Page 548: ...548 Keysight N9927 90001 User s Guide Connector Care Review ...
Page 550: ...550 Keysight N9927 90001 User s Guide Specifications Data Sheet ...
Page 553: ...553 Keysight Handheld Analyzers N99xxA User s Guide D Korean Battery Safety Translation ...
Page 554: ...554 Keysight N9927 90001 User s Guide Korean Battery Safety Translation ...
Page 556: ...556 Keysight N9927 90001 User s Guide Keysight Software End User Licensing Agreement EULA ...
Page 557: ...Keysight N9927 90001 User s Guide 557 Keysight Software End User Licensing Agreement EULA ...
Page 558: ...558 Keysight N9927 90001 User s Guide Keysight Software End User Licensing Agreement EULA ...
Page 565: ......