232 Keysight N9927-90001 User’s Guide
RTSA (Real-Time Spectrum Analyzer) Mode—Option 350 (CPU2 Only)
Record/Playback (RTSA Option)
— Data can be recorded from Traces 1,2,3, or 4 which includes the trace state
(Max Hold, Min Hold, and so forth).
— Data is ALWAYS played back into the same trace number that was
recorded. If four traces were active during the recording, but only one trace
was recorded, then during Playback only that one recorded trace is visible.
Playback Configuration
By default, trace sweeps are played back as fast as the trace can be drawn on
the screen. The following setting allows you to slow playback. In addition, you
can manually scroll through individual traces using Playback Trace, or scroll
through State and User Tags using Playback State/Tag. Learn more in
How to
Playback a Session
“How to Playback a Session” on page 229
.
To slow playback of a session:
— Record a new session or Open an existing session.
— Press
Playback Configuration
— Then
Playback Interval
— Enter a value in seconds between 0 (no delay) and 100 using the numeric
keypad,
arrows, or the rotary knob. After using the keypad, select a
multiplier key. Learn about multiplier abbreviations.
— Press
Enter
Manage Sessions
— Press
Trace 6
— Then
Record Playback
— Then
Record Playback Setup
The following selections are available ONLY
when a session is NOT open.
— Then
Storage Device
to select the media which stores the sessions to be
managed. This is a different setting from the Save/Recall Storage Device
setting.
— Then choose from the following:
—
Internal
FieldFox memory (default)
—
SD Card
An external SD Card (must be inserted)
—
USB
An external USB flash drive (must be inserted)
— Then
Manage Sessions
If these are large recordings on a device, it could take several seconds for
the FieldFox to display the list.
Summary of Contents for N9913A
Page 6: ...6 ...
Page 106: ...106 Keysight N9927 90001 User s Guide NA Network Analyzer Mode NA Mode Settings ...
Page 202: ...202 Keysight N9927 90001 User s Guide SA Spectrum Analyzer Mode Channel Measurements ...
Page 444: ...444 Keysight N9927 90001 User s Guide Noise Figure Mode Option 356 CPU2 Only Troubleshooting ...
Page 470: ...Data Analysis Features All about Scale Settings 470 Keysight N9927 90001 User s Guide ...
Page 546: ...546 Keysight N9927 90001 User s Guide Connector Care Review ...
Page 548: ...548 Keysight N9927 90001 User s Guide Connector Care Review ...
Page 550: ...550 Keysight N9927 90001 User s Guide Specifications Data Sheet ...
Page 553: ...553 Keysight Handheld Analyzers N99xxA User s Guide D Korean Battery Safety Translation ...
Page 554: ...554 Keysight N9927 90001 User s Guide Korean Battery Safety Translation ...
Page 556: ...556 Keysight N9927 90001 User s Guide Keysight Software End User Licensing Agreement EULA ...
Page 557: ...Keysight N9927 90001 User s Guide 557 Keysight Software End User Licensing Agreement EULA ...
Page 558: ...558 Keysight N9927 90001 User s Guide Keysight Software End User Licensing Agreement EULA ...
Page 565: ......