Congratulations on the purchase of our coating
thickness gauge 

Com

Bi

-D3.

Description

The  

Com

Bi

-D3  is a simple and cost effective

measuring device. It belongs to a range of non-
destructive coating thickness gauges.
Measuring ability of 

Com

Bi

-D3:

It is easy and handy to use and allows the user
to make all necessary adjustments with the aid
of   a   menu   (

MODE

–button).   This   allows   for

change to be implemented quickly and simply.
The gauge  

Com

Bi

-D3  can be used for a wide

variety of applications and has to offer a large
measuring   range   from   0   to   3.5   mm.  Modern

electronic and the robust casing guarantee an
extended   lifetime   for   the   high   precision
instruments.

Battery exchange

The

 

Com

Bi-D3

  gauge   is   powered   by   a   9   V

alkaline battery. The battery compartment can
be   found   in   the   top   back   portion   of   the
instrument.   If   a   battery   icon   appears   in   the
display, the battery has to be exchanged.
If   a   replacement   battery   is   not   available
immediately, several measurements can still be
taken   until   the   gauge   shuts   down   completely
(the   display   shows  

bAT

  and   a   discontinuous

beep tone is audible).

Attention:

  Exhausted batteries are hazardous

waste.  Used   batteries   not   with   the   domestic
waste   decontaminate,   but   deliver   at   stated
collective places.

Switching on and off of the device

The gauge can be switched on manually 
via pressing of 

ON/OFF

-button or by 

directly placing the probe on the 
measurement object.

It appears

 

Cd3

 (name of device) and then 

the last measured value.

The gauge switched off automatically after 
40 seconds of non-use or by long pressing 
(about 3 seconds) of 

ON/OFF

-button.

Handling and storage

The  

Com

Bi-D3

  gauge   is   a   high   precision

instrument with a wide scope of applications. It
is therefore of great importance that the device
is handled with care to ensure a long life and a
prerequisite   for   precise   and   accurate
measurement results. The following guidelines
are to be followed to achieve the above:

Protect the device from dust and dirt.

Do not drop the device to the floor.

Protect   the   device   from   moisture,
aggressive vapors and chemicals.

After   use   please   put   the   device   in   the
carrying case.

Avoid   direct   strong   sunlight   and
temperature   shocks  as   these   can  have  a
negative   influence   on   the   measurement
result.

Precise   measurement   results   can   be
achieved   only   with   a   clean   probe.
Therefore,   use   regularly   a   clean,   damp
cloth.

Check the probe regularly for soiling such
as paint or iron particles.

If the device is not used for a long time, it is
advisable   to   remove   the   battery   to   avoid
possible damage caused by the leakage of
a battery.

If   the   device   has   a   failure,   contact   your
supplier for help.

Taking measurements

Hold the device vertically on the location to
be measured.

Place the probe flat (

avoid tipping!

).

To get the best results, place the thumb on
the   elliptical   indicated   position   with   the
other fingers behind the gauge for balance.

A beep is audible and the measured value
appears on the display.

Improper placement, as well as picking up
the   device   before   the   end   of   the
measurement   and   the   zeroing   on   a   non-
metallic   surface   (substrate)   is   displayed
with 

Er0

 (error).

If   the   coating   thickness   exceeds   the
maximum range (3500 µm) or if the device
is placed on the incorrect substrate (wood,
paper, cardboard etc), the display shows 

InF

(infinite).

The V-groove on the measuring head helps
by  measurements  on  round  objects,   such
as rods, tubes, shafts, radii etc.

Please   do   not   perform   measurements   on
magnets and in magnetic fields.
Magnetic fields influence the results by the
Fe-   and   strong   electromagnetic   radiation
has   the   influence   by   the   NFe
measurements.

Zero calibration

A zeroing of the instrument is necessary after
switching   on,   by  different   measurement
processes,   inserting   of   new   battery   or   after
prolonged use.
Place the device on the iron- or the aluminum
plate in the carrying case. You can also use a
piece of uncoated ferro (Fe) or non-ferro (NFe)
metal (substrate) used in your process.  If the
displayed value is out of the basic  tolerance,
the instrument has to be zeroed. The following
steps are to be taken to zero the gauge: 

Remove the device from the zero plate or
the substrate.

Press the  

Zero

  button. The display shows

P0.0

 

(zero point).

Place the gauge on the zero  plate  or the
substrate.  

PIn

  (infinity) appears followed by

a beep tone.

Lift the device at least 5 cm from the zero
plate.  

0.0

  appears   followed   by   another

beep.

To check  the zeroing place the gauge on
the   zero   plate  or  the  substrate  again. 

0.0

should  appear  on  the  display   followed  by
beep.   If   the   result   is   different   repeat   the
zeroing procedure.

The   device   is   now   ready   for   accurate
measurements.

Note that it is not necessarily to receive the
same   displayed   result   by   repeated
measurements   at   the   same   location.
Measurement  variations  can   be caused  by
roughness, dirt or bumps.

The menu of Com

 

 

Bi

   

-D3

The   various   options   from   the   menu   can   be
accessed   by   repeatedly   pressing   the  

Mode

-

button. Pressing the 

Enter

-key allows to select

the   displayed   option.   Now   the  

Mode

-button

change or select the setting. Pressing of 

Enter

confirms your choice and exits the menu.

rST

 -

Resetting the average value (mean)
of the measurements
(

YES

 - Yes, 

no

 - no)

GAG

 -

Choice of substrate material 

AUT

 - automatic detection

(

recommended

) indicated by 

AUTO

icon in the display

FE

 - only steel or iron

nFE

 - non magnetic  metals

(aluminum, copper etc.) 

CnT

 -

continuous measurement indicated
by 

CONT

 icon in the display

(

On

 - On, 

OFF

 - Off

)

UnT

 -

Choice of measuring unit between
microns / mm and mil
(

25.4

 - µm/mm, 

1.

00

 - mil)

bEP

 -

Switching on or off of tons keys
(

On

 - On, 

OFF

 - Off)

Sn

 -

Displays the serial number of the
device

Fe:
all 

non-magnetic 

coatings

 such as 

synthetics, 
lacquers, enamels, 
copper, chromium, 
zinc, etc.

on s

teel or

iron

NFe:
all isolating 
coatings such as 
lacquers, 
synthetics, 
enamels, paper, 
glass, rubber etc.

on 

copper, 

aluminum or brass. 
This includes 
anodized coatings 
on aluminum as 
well.