94
Keysight InfiniiVision 3000T X-Series Oscilloscopes Programmer's Guide
4
Commands Quick Reference
:MEASure:DUAL:VAMPlit
ude
[<source1>][,<source2
>] (see
:MEASure:DUAL:VAMPlit
ude?
[<source1>][,<source2
<source1>,<source2> ::=
CHANnel<n> with N2820A probe
connected
<n> ::= 1 to (# analog channels)
in NR1 format
<return_value> ::= the amplitude
of the selected waveform in volts
in NR3 format
:MEASure:DUAL:VAVerag
e [<interval>]
[,<source1>][,<source
2>] (see
:MEASure:DUAL:VAVerag
e? [<interval>]
[,<source1>][,<source
<interval> ::= {CYCLe | DISPlay}
<source1>,<source2> ::=
CHANnel<n> with N2820A probe
connected
<n> ::= 1 to (# analog channels)
in NR1 format
<return_value> ::= calculated
average voltage in NR3 format
:MEASure:DUAL:VBASe
[<source1>][,<source2
>] (see
:MEASure:DUAL:VBASe?
[<source1>][,<source2
<source1>,<source2> ::=
CHANnel<n> with N2820A probe
connected
<n> ::= 1 to (# analog channels)
in NR1 format
<base_voltage> ::= voltage at the
base of the selected waveform in
NR3 format
:MEASure:DUAL:VPP
[<source1>][,<source2
>] (see
:MEASure:DUAL:VPP?
[<source1>][,<source2
<source1>,<source2> ::=
CHANnel<n> with N2820A probe
connected
<n> ::= 1 to (# analog channels)
in NR1 format
<return_value> ::= voltage
peak-to-peak of the selected
waveform in NR3 format
:MEASure:DUAL:VRMS
[<interval>]
[,<type>]
[,<source1>][,<source
2>] (see
:MEASure:DUAL:VRMS?
[<interval>]
[,<type>]
[,<source1>][,<source
<interval> ::= {CYCLe | DISPlay}
<type> ::= {AC | DC}
<source1>,<source2> ::=
CHANnel<n> with N2820A probe
connected
<n> ::= 1 to (# analog channels)
in NR1 format
<return_value> ::= calculated
RMS voltage in NR3 format
Table 19
:MEASure Commands Summary (continued)
Command
Query
Options and Query Returns
Summary of Contents for InfiniiVision 3000T X Series
Page 1: ...Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide...
Page 40: ...40 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 1 What s New...
Page 50: ...50 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 2 Setting Up...
Page 64: ...64 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 3 Getting Started...
Page 254: ...254 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 8 BUS n Commands...
Page 306: ...306 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 12 DEMO Commands...
Page 364: ...364 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 17 FFT Commands...
Page 442: ...442 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 21 MARKer Commands...
Page 524: ...524 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 22 MEASure Commands...
Page 656: ...656 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 26 POWer Commands...
Page 666: ...666 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 27 RECall Commands...
Page 888: ...888 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 29 SBUS n Commands...
Page 978: ...978 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 30 SEARch Commands...
Page 1240: ...1240 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 38 Error Messages...