736
Keysight InfiniiVision 3000T X-Series Oscilloscopes Programmer's Guide
29
:SBUS<n> Commands
CAN Id specification is set by the :SBUS<n>:CAN:TRIGger:PATTern:ID
and:SBUS<n>:CAN:TRIGger:PATTern:ID:MODE commands.
CAN Data specification is set by the :SBUS<n>:CAN:TRIGger:PATTern:DATA
command.
CAN Data Length Code is set by the
:SBUS<n>:CAN:TRIGger:PATTern:DATA:LENGth command.
Query Syntax
:SBUS<n>:CAN:TRIGger?
The :SBUS<n>:CAN:TRIGger? query returns the current CAN trigger on condition.
Return Format
<condition><NL>
<condition> ::= {SOF | EOF | IDD | DATA | FDD | IDR | IDE | ERR | ACK
| FORM | STUF | CRC | SPEC | ALL | BRSB | CRCD | EBA | EBP | OVER
| MESS | MSIG | FDMS}
Errors
•
See Also
•
"Introduction to :SBUS<n> Commands"
•
•
":SBUS<n>:CAN:TRIGger:PATTern:DATA"
•
":SBUS<n>:CAN:TRIGger:PATTern:DATA:LENGth"
SPECerror
Spec Error (Ack or Form
or Stuff or CRC)
Triggers on Ack, Form, Stuff, or CRC errors.
X
ALLerrors
All Errors
Triggers on all Spec errors and error frames. X
BRSBit
BRS Bit (FD)
Triggers on the BRS bit of CAN FD frames.
X
CRCDbit
CRC Delimiter Bit (FD)
Triggers on the CRC delimiter bit in CAN FD
frames.
X
EBActive
ESI Bit Active (FD)
Triggers on the ESI bit if set active.
X
EBPassive
ESI Bit Passive (FD)
Triggers on the ESI bit if set passive.
X
OVERload
Overload Frame
Triggers on an overload frame.
MESSage
Message
Triggers on a symbolic message.
MSIGnal
Message and Signal
(non-FD)
Triggers on a symbolic message and a
signal value.
FDMSignal Message and Signal (FD,
first 8 bytes only)
Triggers on a symbolic message and a
signal value, limited to the first 8 bytes of
FD data.
* Filtering by CAN IDs is available for these trigger conditions (see :SBUS<n>:CAN:TRIGger:IDFilter).
Condition
Front-panel name
Description
Filter by
ID*
Summary of Contents for InfiniiVision 3000T X Series
Page 1: ...Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide...
Page 40: ...40 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 1 What s New...
Page 50: ...50 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 2 Setting Up...
Page 64: ...64 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 3 Getting Started...
Page 254: ...254 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 8 BUS n Commands...
Page 306: ...306 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 12 DEMO Commands...
Page 364: ...364 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 17 FFT Commands...
Page 442: ...442 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 21 MARKer Commands...
Page 524: ...524 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 22 MEASure Commands...
Page 656: ...656 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 26 POWer Commands...
Page 666: ...666 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 27 RECall Commands...
Page 888: ...888 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 29 SBUS n Commands...
Page 978: ...978 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 30 SEARch Commands...
Page 1240: ...1240 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 38 Error Messages...