:POWer Commands
:POWer:DESKew
Command Syntax
:POWer:DESKew
The :POWer:DESKew command launches the auto deskew process on the
oscilloscope.
Before sending this command:
1
Demagnetize and zero-adjust the current probe.
Refer to the current probe's documentation for instructions on how to do this.
2
Make connections to the U1880A deskew fixture as described in the
oscilloscope's connection dialog or in the
DSOX4PWR Power Measurement
Application User's Guide
.
3
Make sure the voltage probe and current probe channels are specified
appropriately using the :POWer:SIGNals:SOURce:VOLTage1 and
:POWer:SIGNals:SOURce:CURRent1 commands.
The deskew values are saved in the oscilloscope until a factory default or secure
erase is performed. The next time you run the Power Application, you can use the
saved deskew values or perform the deskew again.
Generally, you need to perform the deskew again when part of the test setup
changes (for example, a different probe, different oscilloscope channel, etc.) or
when the ambient temperature has changed.
See Also
•
":POWer:SIGNals:SOURce:VOLTage<i>"
•
":POWer:SIGNals:SOURce:CURRent<i>"
NOTE
Use the lowest attenuation setting on the high voltage differential probes whenever possible
because the voltage levels on the deskew fixture are very small. Using a higher attenuation
setting may yield inaccurate skew values (and affect the measurements made) because the
noise level is magnified as well.
Summary of Contents for InfiniiVision 3000T X Series
Page 1: ...Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide...
Page 40: ...40 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 1 What s New...
Page 50: ...50 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 2 Setting Up...
Page 64: ...64 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 3 Getting Started...
Page 254: ...254 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 8 BUS n Commands...
Page 306: ...306 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 12 DEMO Commands...
Page 364: ...364 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 17 FFT Commands...
Page 442: ...442 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 21 MARKer Commands...
Page 524: ...524 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 22 MEASure Commands...
Page 656: ...656 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 26 POWer Commands...
Page 666: ...666 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 27 RECall Commands...
Page 888: ...888 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 29 SBUS n Commands...
Page 978: ...978 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 30 SEARch Commands...
Page 1240: ...1240 Keysight InfiniiVision 3000T X Series Oscilloscopes Programmer s Guide 38 Error Messages...