48
PowerSaver Technology
If you have opted for PowerSaver Technology (Battery Powered) for your
lock rather than PowerStar Technology (No Battery Required), the power
source for the lock will be a 9 Volt Alkaline or Lithium Battery.
If the lock you have operates with PowerSaver Technology (Battery Pow-
ered) rather than PowerStar Technology (No Battery Required), there will
be one major operational difference. When performing lockoperations, you
do not need to rotate the dial to power the lock.
Low Battery Condition
A low battery condition on the lock will be indicated by rapidly alternating
green and red flashes at the time the lock is opened. If this condition occurs,
complete the appropriate process below as defined by housing type to
replace the battery:
Replace Battery - Low Profile Lock:
1.
Enter a valid combination and open the lock.
Note:
If the existing battery will not provide enough power for you to
open the lock, hold a fresh 9 Volt Alkaline Battery to the lock with
the contacts touching the metal trim encircling the red and green
LEDs. The “+” (positive) battery terminal should cover the red
LED. Enter a valid combination and open the lock while holding
the battery in place.
2.
Locate the battery box mounted inside the door near the lock.
3.
Remove the two Phillips head screws securing the battery box cover.
4.
Note how the battery and the cable are positioned in the box then
remove the battery and battery cable from the battery box.
5.
Unsnap the connector from the old battery and reconnect a fresh 9 Volt
Alkaline or Lithium battery to the battery connector.
6.
Insert the new battery and cable into the battery box, and secure the
cover with the two Phillips head screws.