46
O
PTIONAL
F
EATURES
Silent Duress Alarm
If the silent duress alarm feature is installed on your lock and you have
purchased and installed an Alarm Interface Kit (P/N 301040), an external,
customer supplied alarm can be activated by the lock when a combination
is entered. To activate the silent duress alarm, complete the following steps:
1.
When entering your combination, add 10 to the last two digits of the
PIN.
For example, if the PIN is “526674”, entering “526684” will activate the
silent duress alarm. If the PIN is “526694”, entering “526604” will
activate the alarm. In this case note that “9” becomes “0” and that the
“6” remains unchanged (i.e., no digits are carried over and added to
the “6”).
After the alarm has been activated, normal lock operation is resumed.
Spindle Designation/Bolt Options
The Auditcon locks can be
Spindled
or
Non-Spindled
. There are minor
operational differences between the two, and the bolts associated with
each type can also cause operational differences. The Spindled version of
the lock can operate with a
Standard Deadbolt
, a
Snap Bolt
, or a
Spring
Bolt
. The Non-Spindled version of the lock uses the Kaba Mas
Slide Bolt
.
The Non-Spindled version of the lock does not have a “Home” position
identified in relation to the dial since there is no spindle used to extend and
retract the bolt. There is no “Home” position for the dial since the dial is not
connected to the locking mechanism and does not control retraction or
extension of the bolt.
Spindled Technology:
There is a “
Home
” position for the dial on the lock that is directly
related to the turning of the spindle and retraction or extension of the
bolt. The dial must be positioned here on a lock “Open’’ operation
before you can successfully open the lock.