13. Enter the two-digit number that represents the ending minute within the
hour again for verification. Simultaneous green and red flashes
display.
Caution:
When setting time windows for a specific day/window code at
the lock, both the first and second window for that day/window
code must be set. If you are not actually using the second time
window, set it to the same time period as the first time window
for the day/window code. If only one time window is set for a
day/window code, the second window will override the first
window with the default of 24 hour a day access.
Note:
Time Windows can also be set at the PC using the Auditcon
Audit Only for Windows Software (Version 3.1 or greater.) The
Time Windows can then be uploaded to the lock using an SA
Key. See Upload Time Windows.
Upload Time Windows
As an alternative to defining Time Windows at the lock, they can be defined
at the PC using the Auditcon Audit Only for Windows software and the
information can then be transferred to the lock via an SA Key.
Note:
The Upload Time Windows operation requires an SA key that
has been properly prepared at the PC using the Auditcon Audit
Only for Windows software.
To upload time windows, complete the following steps:
1.
For a PowerStar version of the lock, power the lock by briskly turning
the dial back and forth in both directions.
2.
Press
Enter
and then
8
. Simultaneous green and red flashes display.