11
Sample Lock Setup/Operation
The following provides a general example of how to perform the setup
activities for the Auditcon 100, 200, 400, 500 Series Lock. This example
demonstrates how to set up the lock in Independent mode with Single User
access. If you would like to set up your lock in this manner (defining your
own values for User IDs and PINs), you can follow the steps outlined in this
example. For a definition of all lock modes and for detailed information on
lock setup activities and lock operations, you should refer to the appropriate
sections in this guide. If at any time the lock powers down, you should turn
the dial in any direction until simultaneous green and red flashes display
and two beeps sound to indicate that the lock is powered.
Warning:
A Super Master PIN can be set and then used to shelve
the lock in the event that the Master User combination is lost.
If you do not set the Super Master User PIN prior to complet-
ing the activities in the following example, all Super Master
User capabilities will be permanently lost. Refer to “Set
Super Master User PIN” on page 7 or page 19 for more
detailed information.
I. Set Master User PIN
The default PIN assigned to the Master User is “120943”. You must change
this default PIN before the Master User combination (Master User ID + PIN)
can be used to perform lock operations. Change the Master User PIN to
“123456” by completing the following:
1.
For a PowerStar version of the lock, power the lock by briskly turning
the dial back and forth in both directions.
2.
Press
Enter
and then
1
. Simultaneous green and red flashes display.
3.
Enter two-digit Master ID
00
followed by default Master User PIN
120943
. Simultaneous green and red flashes display.
4.
Enter two-digit Master ID
00
followed by new Master User PIN
123456
.
Simultaneous green and red flashes display.
5.
Enter two-digit Master ID
00
and new Master User PIN
123456
again.
Simultaneous green and red flashes display.