26
Toggle Sound On/Off
Note:
Only a Master User can toggle the sound on/off. This toggle can
be changed at any time except when the lock is in shelved
mode, when the lock is disabled, or during a time delay period.
A Master User can toggle the sound “on” so that one beep sounds each
time the lock LED flashes. To toggle the sound of these beeps “on” or “off”,
complete the following steps:
1.
For a PowerStar version of the lock, power the lock by briskly turning
the dial back and forth in both directions.
2.
Press
Enter
and then
9
. Simultaneous green and red flashes display.
3.
Enter the Master User combination. Simultaneous green and red
flashes display.
Note:
Some lock sound responses can never be turned off. There are
two situations in which the lock will beep regardless of whether
the sound is toggled “off” or “on”. The beeps that sound to
indicate that a PowerStar lock is powered will always occur as
will the beeps that sound during the open window after a delay
period.
Note:
If you have completed an operation but the lock has powered
down, two simultaneous green and red flashes will display but
no beeps will sound.
Change Reporting Capabilities
Note:
Only a Master User can change the reporting capabilities of lock
personnel.
When shipped from the factory, the default reporting mode of the lock
enables all lock personnel (Master User, Access Users, Supervisors and
Subordinate Users) to retrieve audit records or to retrieve User information.
However, the Master User can limit the reporting capabilities, as shown in
the following chart, depending on the lock model.