33
4.
When the delayed opening window has begun, re-enter the same
combination. If operating in Single User access and the combination is
entered successfully, the lock indicates that it is ready to open by
displaying the following:
Spindled PowerStar
- 1 slow green flash
Spindled PowerSaver
- Continuous green flashes for approx. 5
seconds
Non-Spindled PowerStar
- Continuous green flashes for approx. 5
seconds
Non-Spindled PowerSaver
- Continuous green flashes for approx. 5
seconds
If operating in Dual User access, simultaneous green and red flashes
display.
5.
If operating in Dual User access, enter the second valid combination. If
the combination is entered successfully, the lock indicates that it is
ready to open by displaying the following:
Spindled PowerStar
- 1 slow green flash
Spindled PowerSaver
- Continuous green flashes for approx. 5
seconds
Non-Spindled PowerStar
- Continuous green flashes for approx. 5
seconds
Non-Spindled PowerSaver
- Continuous green flashes for approx. 5
seconds
6.
For a
Spindled
version of the lock, dial right (clockwise) until the lock
bolt is retracted and then open the container. If you have a
Spring Bolt
,
you must dial right and hold the dial until the container has been
opened so that the bolt does not “spring” back into the extended
position. For a
Non-Spindled
version of the lock, engage the container
boltworks to unlock the lock and open the container simultaneously.
Note:
The lock will not accept any “
Enter
” commands during a
delayed opening.