18
•
If the lock is powered but you have not started an operation, you are
allotted the time until the lock powers down to begin an operation.
Lock Responses
•
For a PowerStar version of the lock, simultaneous green and red
flashes display and two beeps sound to indicate that the lock is
powered. Beeps sound to indicate that there is enough power for the
next operation to be performed. If no beeps sound, you must power the
lock by turning the dial in any direction.
•
After each accepted step of an operation, simultaneous green and red
flashes display prompting you to enter additional information for the
next step of the operation.
•
After you have completed all the steps of an operation, two simulta-
neous green and red flashes display if the operation is successful.
Three red flashes display if the operation is unsuccessful and you will
need to re-key the operation that caused the error.
•
If a valid combination or combinations are entered to open the lock, the
lock will respond as follows to indicate that the lock is ready to open:
Spindled PowerStar
- 1 slow green flash
Spindled PowerSaver
- Continuous green flashes for approx. 5
seconds
Non-Spindled PowerStar
- Continuous green flashes for approx. 5
seconds
Non-Spindled PowerSaver
- Continuous green flashes for approx. 5
seconds
•
After five consecutive failed entry attempts (invalid combinations), the
lock will disable for three minutes. Slow red flashes display during this
period. Any additional failed entry attempts (after the first five consecu-
tive attempts) result in the lock disabling for three minutes after each
failed entry attempt. The count of failed entry attempts accumulates
even if the lock powers down between attempts.
•
Six red flashes indicate an internal error. If this occurs, the lock can only
be opened using the Master User combination. This is the only
instance in which the Master User combination can open the lock.
•
After each keystroke a green flash is displayed. A beep will also sound
if the sound is toggled “on”. If the lock does not respond, either the lock
has powered down or the key was not pressed properly.
Summary of Contents for AUDITCON 100 series
Page 1: ...OPERATING INSTRUCTIONS AUDITCON LOCK 100 200 400 500 SERIES...
Page 56: ...52...
Page 57: ...NOTES...
Page 58: ......